Salem, OR Outdoor Lighting: Dark Sky Rules (2026)
Key Facts
- Governing section
- SRC 800.060
- Lot-line illumination cap
- 5 foot-candles, or shielded
- Applies to
- All development, every zone
- EC zone cutoff limit
- 2.5% candlepower above 90°
- EC zone residential buffer cap
- 0.5 horizontal foot-candles
Summary
Salem's development code caps exterior lighting citywide: fixtures cannot shine or reflect onto neighboring properties or cast glare onto the public right-of-way, and light sources must be shielded or limited to five foot-candles at the lot line under SRC 800.060.
Exterior lighting shall not shine or reflect onto adjacent properties, or cast glare onto the public right-of-way. Exterior light fixtures shall be located and designed so that the light source, when viewed at a height of five feet above the ground at a distance of five feet outside the boundary of the lot, shall be either: (1) Completely shielded from direct view; or (2) No greater than five foot-candles in illumination.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 26 Update 1).
Full Breakdown
005 applies to all development in every zone unless a more specific UDC provision is more restrictive. 060, Exterior lighting, sets two baseline requirements. First, exterior lighting shall not shine or reflect onto adjacent properties, or cast glare onto the public right-of-way. Second, exterior light fixtures must be located and designed so that, when the light source is viewed at a height of five feet above the ground at a distance of five feet outside the lot boundary, it is either completely shielded from direct view or produces no more than five foot-candles of illumination.
That test effectively forces full-cutoff or shielded fixtures on lot lines, since an unshielded bulb visible from just outside the property would otherwise have to stay under the five foot-candle ceiling to comply. The rule applies to any development activity subject to UDC review, including commercial, industrial, and multi-family sites, and is enforced during site plan review and building permit issuance by the Salem Community Development Department's Planning Division. 5 horizontal foot-candles, unless the fixture is shielded to the same cutoff or is a non-cutoff luminaire emitting no more than 10,000 lumens per pole. 060 and Ordinance No. 31-13, the 2013 UDC recodification.
Violations & Fines
Lighting that fails the shielding or foot-candle test at the lot line is a code compliance matter handled through Salem's Community Development Department, which can require retrofitting or reorienting fixtures as a condition of an occupancy permit or in response to a neighbor complaint. Because SRC 800.060 sits in the General Development Standards chapter, a fixture out of compliance can also hold up sign-off on a site plan review, building permit, or certificate of occupancy until it is corrected.
Frequently Asked Questions
Does Salem require dark-sky or full-cutoff fixtures everywhere?
Are commercial and industrial properties held to a stricter lighting standard?
Who enforces Salem's exterior lighting rules?
Sources & Official References
Other rules in Salem
Compare Salem to another location·View the Oregon outdoor lighting overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.