Tempe, AZ Outdoor Lighting: Dark Sky Rules (2026)
Key Facts
- Maximum on-site illumination
- 40 foot-candles measured at the surface
- White/opal lens, non-cutoff
- 1,700 lumens maximum
- Clear/prismatic lens, non-cutoff
- 600 lumens maximum
- Residential property line limit
- 0.5 foot-candle next to a single-family district
- Freestanding fixture height
- 18, 25 or 30 feet depending on distance to residential
- Mercury vapor fixtures
- Installation prohibited under Section 4-804
- Approving authority
- Community Development Director or designee, before installation
Summary
Tempe caps on-site outdoor lighting at 40 foot-candles measured at the surface and sorts fixtures by how much light escapes upward. Full cutoff fixtures can use any source up to that cap, while non-cutoff fixtures with white/opal lenses are limited to 1,700 lumens and clear or prismatic lenses to 600 lumens.
Illumination Levels The maximum illumination level for on-site lighting is forty (40) foot-candles as measured at surface based on light loss factor of sixty-eight percent (0.68) for metal halide lighting and seventy-two percent (0.72) for high pressure sodium lighting. Refer to Section 4-805 Exemptions. [...] b. Outdoor light fixtures, which are full cutoff to direct all light below a horizontal plane through the bottom of the fixture and have no lens which drops below the fixture may use any illumination source, up to a maximum of forty (40) foot-candles, as provided in Section 4-803 (B); c. Outdoor light fixtures, which have a lens or diffuser which is visible above the horizontal plane and constructed of white/opal glass, are considered non-cutoff and filtered and shall be limited to the light output no greater than one thousand seven hundred (1,700) lumens; d. Outdoor light fixtures, which have a lens or diffuser which is visible above the horizontal plane and constructed of clear or prismatic glass, are considered non-cutoff and non-filtered and shall be limited to the light output no greater than six hundred (600) lumens;
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: City Code: Supplement 33 Update 4 | Zoning and Development Code: Supplement 11 Update 2).
Full Breakdown
Tempe's dark-sky rules sit in Chapter 8 (Lighting) of Part 4 of the Zoning and Development Code. Section 4-801 states the purpose: lighting that supports way-finding and crime prevention while minimizing glare onto adjoining properties and light pollution into the nighttime sky. The chapter applies to lighting for uses on-site. Streetlights in the public right-of-way fall outside it and follow the City of Tempe Public Works Department Standard Details.
The sky-protection standard is a cap plus a fixture test. Section 4-803(B) caps on-site illumination at forty (40) foot-candles measured at the surface, calculated with a light loss factor of 0.68 for metal halide and 0.72 for high pressure sodium. Section 4-803(C)(5) then sorts fixtures by how much light escapes upward. A full cutoff fixture, one that directs all light below a horizontal plane through the bottom of the fixture and has no lens dropping below it, can use any illumination source up to the 40 foot-candle ceiling. A fixture with a lens or diffuser visible above the horizontal plane is non-cutoff. If that lens is white or opal glass it is filtered and limited to 1,700 lumens. If it is clear or prismatic glass it is non-filtered and limited to 600 lumens.
Neighbors get separate protection. Under (C)(5)(f), light from the proposed fixtures cannot exceed one-half (0.5) foot-candle at a property line next to a single-family district, and lighting next to a residential use cannot spill onto that use. Freestanding fixtures are height-limited to 18 feet in or within 50 feet of a residential district, 25 feet in the next 50 to 150 feet, and 30 feet in all other locations, measured from the top of the fixture to the surface at the base of its support. Section 4-804 prohibits installing mercury vapor fixtures.
The process runs through permits. All exterior lighting installations need the approval of the Community Development Director or designee before installation, and anyone applying for a building, electrical or sign permit must submit evidence of compliance. Section 4-802 requires a photometric plan whose contents follow Appendix E. Standards in the RCC district and all MU districts are set through Development Plan Review under Section 6-306. Swapping in different fixtures or lamps after a permit is issued requires the Director's approval of the change.
Section 4-805 carves out exemptions. Lighting for single-family homes and accessory buildings is exempt if no measurable light spills onto adjacent property. Ball fields, golf courses and similar sporting venues are exempt from the height and shielding rules and can exceed 40 foot-candles until 11:00 p.m. Autoplex automobile dealerships get up to 80 foot-candles at display areas until 11:00 pm.
Violations & Fines
Chapter 8 prints no fine schedule of its own. Enforcement runs through the permit gate: the Community Development Director or designee must find the plans conforming and stamp and sign them before a building, electrical or sign permit issues, and plans that exceed the 40 foot-candle cap, the 0.5 foot-candle residential property-line limit or the lumen limits are not stamped. Mercury vapor fixtures cannot be installed.
Frequently Asked Questions
What is the maximum light level allowed on a Tempe commercial site?
How does Tempe treat fixtures that shine light upward?
How much light can spill onto a neighboring single-family lot in Tempe?
Do I need approval before installing outdoor lights in Tempe?
Can I install mercury vapor lights in Tempe?
Sources & Official References
Other rules in Tempe
Compare Tempe to another location·View the Arizona outdoor lighting overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Dark Sky Rules in Nearby Cities
How other cities in Maricopa County handle dark sky rules.