Tonawanda, NY Outdoor Lighting: Dark Sky Rules (2026)
Key Facts
- Fixture shielding
- mandatory, pointing downward
- Max illumination cone angle
- 60 degrees (90 if under 3 ft)
- Applies to
- nonresidential, mixed-use, multi-family over 4 units
- Dark Sky Association compliance
- encouraged, not mandatory
- Penalty
- up to $250/day, 15 days jail
Summary
Commercial and multi-family lighting in the Town of Tonawanda must be fully shielded and pointed downward under the Zoning Law's dark-sky-minded design standards, which cap the light cone at 60 degrees from vertical and encourage International Dark Sky Association compliant fixtures.
§ 215-33.1. Purpose and intent. ... B. Permit the use of exterior lighting that does not exceed the minimum levels specified in the International Dark Sky Association and the Illuminating Engineering Society of North America recommended practices for night-time safety, utility, security, productivity, enjoyment, and commerce. ... § 215-33.2. Applicability. A. Uses subject to regulation. These regulations shall apply to all exterior lighting on any property utilized for the following purposes: (1) Nonresidential uses, including industrial uses; (2) Mixed-uses, whether located on the same site or within the same structure; and (3) Multi-family dwellings over four units. ... § 215-33.4. Lighting design. A. The use of lighting fixtures compliant with International Dark Sky Association standards is highly encouraged. B. Fixtures shall be fully shielded, pointing downward, to minimize skyglow, glare, and light trespass. Luminaries shall be so hooded or shielded that the maximum angle of the cone of direct illumination shall be 60° drawn perpendicular to the ground.
Full Breakdown
Article 33 of the Zoning Law, Exterior Lighting, states its purpose at § 215-33.1: permit lighting needed for visibility and security while keeping it within the minimum levels recommended by the International Dark Sky Association and the Illuminating Engineering Society of North America, curtailing light pollution and skyglow and minimizing offsite impacts like light trespass. Applicability is set at § 215-33.2.A: these standards reach nonresidential uses including industrial uses, mixed-use development, and multi-family dwellings over four units, all requiring development plan review approval under Article 42 before any exterior lighting is erected.
The Town Board's operative design rule sits at § 215-33.4: Subsection A encourages, without requiring, fixtures compliant with International Dark Sky Association standards, while Subsection B imposes a mandatory shielding standard: fixtures shall be fully shielded and pointed downward to minimize skyglow, glare and light trespass, with luminaries hooded so the cone of direct illumination is capped at a 60-degree angle from perpendicular, an angle that can widen to 90 degrees only for fixtures mounted less than three feet above grade. A lighting plan meeting Article 33's specifications, prepared by a lighting professional, must be filed with the development plan review application before the Code Enforcement Officer or reviewing body can approve any covered project's exterior lighting.
Violations & Fines
Failing to shield fixtures or exceeding the 60-degree illumination cone required by § 215-33.4.B is a Zoning Law violation enforceable under § 215-12.2: a fine of up to $250, up to 15 days' imprisonment, or both, with each day noncompliant lighting remains in place counted as a separate offense.
Frequently Asked Questions
Does Tonawanda require Dark Sky certified light fixtures?
How far can a parking-lot light point outward?
Do these lighting rules apply to a homeowner's porch light?
Sources & Official References
Other rules in Tonawanda
New York rules heatmap·Compare Tonawanda to another location·View the New York outdoor lighting overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.