Centennial, CO Outdoor Lighting: Light Trespass & Shielding (2026)
Key Facts
- LZ0 cap
- 0.1 footcandles at property line
- LZ4 cap
- 1.5 footcandles at property line
- Measured at
- receiving property's line
- Applies to
- new development, substantial changes
Summary
Centennial limits how much light can spill from one property onto its neighbor, capping illuminance at the shared property line from 0.1 to 1.5 foot-candles by Lighting Zone.
D.Spill Light Limits. Lighting Zones designate how much spill light is permitted onto a property from an adjacent property. The relevant Lighting Zone is the one for the property receiving the light from an adjacent property. Spill light may be measured by either horizontal measurements at grade or by vertical measurements at the property line up to the height of the highest window on the property receiving the spill light. Where vertical measurements at the property line are impractical, measurements at windows may be substituted.E.Exceptions to Spill Light Limits. All exterior lighting shall comply with the spill light limits set in Table 12-6-705C, Spill Light-Maximum Limits, except:1.Spill light onto public rights-of-way at entries to a property may be the greater of one third of the maximum allowed illuminance for the parking area on the property or one third of the maximum allowed illuminance for the roadway; and2.When the maximum light spill at a boundary between two properties exceeds the limits specified in Table 12-6-705C, Spill Light-Maximum Limits, due to the contributions from existing lighting located on either the receiving property or another adjacent property not subject to the proposed development or redevelopment. Table 12-6-705C Spill Light - Maximum Limits Lighting Zone Maximum Horizontal or Vertical Measured Illuminance at the Property Line, Excluding Public Rights-of-way (footcandles)
LZ0 0.1 LZ1 0.2 LZ2 0.4 LZ3 0.8 LZ4 1.5
Full Breakdown
LDC § 12-6-705(D) caps 'spill light', light crossing onto a neighboring property, based on the Lighting Zone assigned to the property receiving it, not the source. Table 12-6-705(C) sets the ceiling at the property line: 0.1 foot-candles in LZ0, rising to 0.2 in LZ1, 0.4 in LZ2, 0.8 in LZ3, and 1.5 in LZ4. The City measures spill light either horizontally at grade or vertically at the property line up to the height of the highest window on the receiving property. Entries onto public rights-of-way get a partial exception tied to parking-lot or roadway illuminance limits.
Violations & Fines
LDC lighting violations are minor offenses; the City may issue cease-and-desist orders, and municipal court can fine up to $2,650 per day of continued noncompliance (§§ 12-15-201, 12-15-302, 1-4-10).
Frequently Asked Questions
What if my neighbor's floodlight shines onto my yard in Centennial?
How is light trespass measured in Centennial?
Sources & Official References
Other rules in Centennial
Compare Centennial to another location·View the Colorado outdoor lighting overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Light Trespass & Shielding in Nearby Cities
How other cities in Arapahoe County handle light trespass & shielding.