Coeur d'Alene, ID Outdoor Lighting: Light Trespass & Shielding (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

CC district lighting cap
Greater than 2 foot-candles is prohibited
NC district lighting cap
Greater than 1 foot-candle is prohibited
Fixture design
Cutoff design to prevent spillover
Business park rule
Shielded to avoid glare on adjoining building sites
Electronic sign brightness
0.3 foot candles above ambient light
Default infraction penalty
$100 under § 1.28.010

Summary

In the City of Coeur d'Alene, Idaho, lighting greater than two foot-candles is prohibited in a Community Commercial (CC) district, and every fixture must be a cutoff design to prevent spillover. Neighborhood Commercial sites face a one foot-candle cap, and business parks must shield lighting to avoid glare on adjoining building sites.

The following design standards shall apply to all uses within a CC district: ... ... F. Lighting greater than two (2) foot-candles is prohibited. All lighting fixtures shall be a "cutoff" design to prevent spillover.

Full Breakdown

Section 17.05.1270 lists the design standards that apply to all uses within a CC district, and item F is the light spillover rule: lighting greater than two (2) foot-candles is prohibited, and all lighting fixtures shall be a "cutoff" design to prevent spillover. The code does not name a measuring point, so the two foot-candle figure and the cutoff requirement are the operative words.

The Neighborhood Commercial district has the same rule with a tighter number. Section 17.05.1070(F) prohibits lighting greater than one foot-candle and requires the same "cutoff" fixture design to prevent spillover. Signs are handled in Title 15: an illuminated Sign, including an Electronic Message Display, must have technology that automatically dims according to ambient light conditions, and the display shall not operate at brightness levels of more than 0.3 foot candles above ambient light, measured at 100 feet for signs of 0 to 100 square feet, 150 feet for 101 to 350 square feet, 200 feet for 351 to 650 square feet and 250 feet for 651 to 672 square feet (§ 15.50.400(D)). Billboard lighting must be directed toward the display surface and, if necessary, shielded to prevent light from interfering with the quiet enjoyment of nearby properties (§ 15.50.400(C)).

Commercial business parks have their own sentence in § 17.07.765: each building site shall have adequate lighting for structures, parking and storage areas, walkways and vehicle entrances and exits, and lighting shall be shielded to avoid casting glare on adjoining building sites.

Glare is also a citywide performance standard. Under § 17.07.130, in a manufacturing district intense glare produced by an activity shall not be detrimental beyond the boundary of the district, and in all other zoning districts a use producing intense glare shall be carried out within a completely enclosed structure so that neither a public nuisance nor hazard is created at or beyond lot lines. Section 17.07.110 prohibits any use that violates those standards even where the zone otherwise permits it.

Violations & Fines

A fixture that is not a cutoff design, or lighting above the foot-candle cap, violates a mandatory design standard. Under § 1.28.010 that is a misdemeanor unless an infraction penalty is provided: a fine of not more than $1,000, up to 180 days in jail, or both. The default infraction penalty is $100, and each day is a separate offense.

Frequently Asked Questions

What is the lighting limit in a Community Commercial district in the City of Coeur d'Alene?
Section 17.05.1270(F) prohibits lighting greater than two (2) foot-candles in a CC district. It also requires all lighting fixtures to be a cutoff design to prevent spillover. The Neighborhood Commercial district sets a lower cap of one foot-candle in § 17.05.1070(F).
What kind of fixtures are required?
Both the CC and NC design standards require all lighting fixtures to be a cutoff design to prevent spillover. Business parks follow § 17.07.765 instead, which says lighting shall be shielded to avoid casting glare on adjoining building sites. The CC cap is two foot-candles and the NC cap is one.
Do electronic signs have a brightness limit?
Yes. Section 15.50.400(D) says an Electronic Message Display shall not operate at brightness levels of more than 0.3 foot candles above ambient light. It is measured with a foot-candle meter at a distance that depends on sign area, from 100 feet up to 250 feet.
Does intense glare from an industrial site have to stay on its own lot?
In a manufacturing district, § 17.07.130 says intense glare shall not be detrimental beyond the boundary of the district. In all other districts, a use producing intense glare shall be carried out within a completely enclosed structure so no public nuisance or hazard is created at or beyond lot lines.

Sources & Official References

Other rules in Coeur d'Alene

All Coeur d'Alene rules

Compare Coeur d'Alene to another location·View the Idaho outdoor lighting overview

Get notified when Light Trespass & Shielding in Coeur d'Alene, ID changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.