Outdoor Lighting in Pomona, CA (2026)

2 verified outdoor lighting rules for Pomona, California, sourced directly from the municipal code and official government pages.

Verified from official government sources

Dark Sky Rules

Pomona Outdoor Lighting Shielding RulesSome Restrictions

Pomona's Zoning and Development Code requires nearly all outdoor light fixtures to be full cutoff and shielded, banning searchlights, skyward beams, and dished cobra-head fixtures. Parking lot lights top out at 30 feet, pedestrian pole lights at 15 feet, and any project adding parking or pedestrian lighting must submit a photometric plan proving compliance before permits issue.

Key Facts

Effective date
July 1, 2024 (Zoning and Development Code)
Parking lot light height cap
30 feet
Pedestrian light height cap
15 feet
Non-cutoff exception
fixtures under 9,500 initial lumens
Prohibited fixtures
searchlights, dished cobra-head lenses
Permit trigger
photometric plan required for new lighting
Color rendering minimum
CRI 80 or higher

a. Lighting Sources Not Permitted ...2. Temporary searchlights and other high-intensity narrow-beam, moving fixtures that shine light directly up to the sky. ...c. Parking and Pedestrian Area Lighting ...3. All light fixtures must be full cutoff (shielded), except as listed below.

4. Non-cutoff (unshielded) fixtures can be used when the maximum initial lumens generated by each fixture is less than 9,500. These fixtures generally feature globes or vertical glass planes and must be coated with an internal white frosting to diffuse light.

Full breakdown

Section 640.A of the Zoning and Development Code, adopted July 1, 2024, sets Pomona's exterior lighting standards and applies to every fixture installed after that date, plus any replacement, wattage change, or relocation of an existing fixture (640.A.2). Two categories of fixtures are barred outright: cobra-head-type fixtures with dished or drop lenses that use non-incandescent sources, and temporary searchlights or other high-intensity narrow-beam moving fixtures that shine light directly up into the sky (640.A.3.a). For everything else, the default rule under 640.A.3.c is full cutoff, meaning the fixture housing must fully shield the lamp so no light escapes above the horizontal plane.

The code allows one narrow exception: non-cutoff, unshielded fixtures rated below 9,500 initial lumens, provided they use globes or vertical glass panes coated with an internal white frosting to diffuse the glow. Height caps reinforce the shielding requirement: pole-mounted lights in parking lots and other vehicle-use areas cannot exceed 30 feet, and pole-mounted pedestrian-area fixtures cannot exceed 15 feet. Floodlights get their own rule (640.A.3.d): each fixture must be aimed at least 45 degrees down from vertical, or the fixture front must be shielded so no part of the bulb extends below the shield's bottom edge, and any floodlight within 50 feet of a street right-of-way must aim perpendicular to that right-of-way within a 15-degree side-to-side tolerance.

Every fixture must also carry a Color Rendering Index of 80 or higher, and service connections to freestanding fixtures must run underground. Any project that adds parking or pedestrian-area lighting has to submit a photometric plan to Development Services demonstrating the layout meets these standards before a permit is issued; routine maintenance like relamping or ballast swaps on existing fixtures does not trigger review.

Violations & penalties

Pomona reviews outdoor lighting for compliance at the permit stage: a photometric plan must accompany any application adding parking or pedestrian-area lighting, and Development Services can reject a plan that shows non-cutoff fixtures above the 9,500-lumen threshold, searchlights, or cobra-head dished fixtures. Existing fixtures are exempt from retrofitting unless they are replaced or relocated, at which point the new installation must meet current standards. Code Compliance investigates unpermitted or nonconforming installations reported by neighbors.

Dark Sky Rules FAQ

Does Pomona require all outdoor lights to be shielded?
Yes for parking lots and pedestrian areas: Sec. 640.A.3.c makes full cutoff shielding the default rule. The only exception is a fixture under 9,500 initial lumens with a frosted glass or globe diffuser, which can stay unshielded under 640.A.3.c.4.
Can I install a decorative unshielded post light in my yard?
The lumen-based exception in Sec. 640.A.3.c.4 covers any fixture under 9,500 initial lumens fitted with a frosted diffuser, residential post lights included, so most yard fixtures qualify without full cutoff shielding as long as they stay under that lumen cap.
How tall can parking lot light poles be in Pomona?
Sec. 640.A.3.c.1 caps pole-mounted fixtures in parking lots and other vehicle-use areas at 30 feet, while Sec. 640.A.3.c.2 caps pole-mounted pedestrian-area fixtures at 15 feet.
Do floodlights follow the same shielding rule as other fixtures?
No. Floodlights follow the separate standard in Sec. 640.A.3.d: each must be aimed at least 45 degrees down from vertical or have its bulb fully recessed behind a shield, and units within 50 feet of a street must aim perpendicular to it within a 15-degree tolerance.

Sources & official references

Light Trespass & Shielding

Pomona Light Trespass LimitsSome Restrictions

Pomona caps how much outdoor light can spill onto neighboring land: Sec. 640.A.3.b limits illumination at any street right-of-way line to an average of 2.5 footcandles with no more than a 4:1 uniformity ratio, and separately bars fixtures from being oriented onto adjacent properties, streets or sidewalks. The rule applies to lighting added or altered under the July 1, 2024 Zoning and Development Code.

Key Facts

Max illumination at street ROW
2.5 footcandles average
Max uniformity ratio
4:1
Orientation ban
cannot aim onto adjacent properties, streets, sidewalks
Minimum CRI
80 or higher
Effective date
July 1, 2024
Compliance check
photometric plan required at permitting

1. The maximum light level of any light fixture measured at the right-of-way line of a street cannot exceed an average of 2.5 footcandles. The uniformity ratio should be no more than 4:1. ...3. Lighting cannot be oriented onto adjacent properties, streets or sidewalks.

Full breakdown

Section 640.A.3.b of the Zoning and Development Code, effective July 1, 2024, is Pomona's light-trespass control and sets two independent limits. First, a footcandle ceiling: the maximum light level from any fixture, measured at the right-of-way line of a street, cannot exceed an average of 2.5 footcandles, and the uniformity ratio (the spread between the brightest and dimmest points) cannot exceed 4:1, which keeps a property from washing the street or a neighbor's frontage in uneven glare. Second, an orientation ban: lighting cannot be oriented onto adjacent properties, streets or sidewalks under 640.A.3.b.3, so a fixture aimed to spill directly across a property line into a neighbor's yard or window is noncompliant even if it stays under the footcandle cap.

These standards sit alongside the full-cutoff shielding rule in 640.A.3.c and the floodlight aiming rule in 640.A.3.d, both of which also work to keep light on the source property: floodlights within 50 feet of a right-of-way must aim perpendicular to it within a 15-degree tolerance, and all light sources must carry a Color Rendering Index of 80 or higher. The standards apply to any fixture installed after July 1, 2024 and to any existing fixture that is replaced, relocated, or has its wattage or type changed under 640.A.2.b.2; simple relamping or ballast swaps are exempt.

Any project adding parking or pedestrian-area lighting must submit a photometric plan under 640.A.2.c showing compliance with the footcandle and orientation limits before Development Services will issue a permit.

Violations & penalties

Development Services checks light-trespass compliance through the required photometric plan before issuing a permit for new parking or pedestrian-area lighting; a plan showing more than 2.5 average footcandles at the right-of-way, a uniformity ratio worse than 4:1, or fixtures aimed at a neighboring lot gets rejected. Code Compliance can act on a neighbor's complaint about glare from an existing installation that was altered without being brought into compliance.

Light Trespass & Shielding FAQ

How bright can a light be at my property line in Pomona?
Sec. 640.A.3.b.1 caps light measured at the street right-of-way line at an average of 2.5 footcandles with a uniformity ratio no worse than 4:1, so a fixture that blows past that average or creates sharp hot spots fails the standard.
Can a neighbor point a security light straight at my yard?
No. Sec. 640.A.3.b.3 says lighting cannot be oriented onto adjacent properties, streets or sidewalks, so aiming a fixture across the property line into your yard violates the code regardless of its brightness.
Who enforces Pomona's light trespass rule?
Development Services reviews the required photometric plan before permitting new parking or pedestrian lighting, and Code Compliance follows up on complaints about existing fixtures that spill light onto neighboring property.
Does the footcandle limit apply to residential yard lights too?
Sec. 640.A applies to any fixture installed or altered after July 1, 2024 without limiting itself to commercial sites, so a residential floodlight or post light aimed toward the street or a neighbor's lot is subject to the same footcandle and orientation rules.

Sources & official references

Looking for Los Angeles County county-wide rules?

County ordinances apply to unincorporated areas and may supplement Pomona city rules.

Outdoor Lighting in Los Angeles County →