Key Facts
- Trigger size
- gross floor area of 3,000 square feet or more
- Base requirement
- at least one (1) off-street loading space
- Additional spaces
- one (1) for each ten thousand (10,000) square feet or fraction thereof
- Min. dimensions
- 12 ft x 65 ft x 14 ft
- Residential setback
- 50 feet minimum
- Access rule
- Forward-motion entry/exit
Summary
In unincorporated Franklin County, structures with a gross floor area of 3,000 square feet or more that are used for manufacturing, warehousing, retail or similar uses must provide off-street loading space on the same lot. The county also sets the size, clearance, setback and access for each space.
Structures having a gross floor area of 3,000 square feet or more and occupied by: Manufacturing, storage and/or warehousing, goods display, retail and/or wholesale store... shall provide and maintain on the same lot of the structure in question at least one (1) off-street loading space and one (1) additional loading space for each ten thousand (10,000) square feet or fraction thereof of gross floor area in excess or three thousand (3,000) square feet.
Full Breakdown
Franklin County Zoning Resolution § 531.03 applies when a structure meets a size test and a use test together. The size test is a gross floor area of 3,000 square feet or more. The use test is occupancy by manufacturing, storage and/or warehousing, goods display, a retail and/or wholesale store, or a similar use that involves the receipt and distribution of goods.
A covered structure must provide and maintain its loading space on the same lot of the structure in question. The words "provide and maintain" make this a continuing duty in Franklin County, and the same-lot wording means the space cannot be placed on a different parcel.
The count works in steps. Every covered structure needs at least one (1) off-street loading space. It then needs one (1) additional loading space for each ten thousand (10,000) square feet or fraction thereof of gross floor area in excess of three thousand (3,000) square feet. Because a fraction of 10,000 square feet counts the same as a full 10,000, floor area above the 3,000 square foot threshold adds to the requirement before a full 10,000 square feet of excess is reached.
Related sections of the Zoning Resolution control the design. § 531.031 sets a minimum space of 12 feet by 65 feet with 14 feet of vertical clearance. § 531.032 bars a loading space within 50 feet of any Residential or Planned Residential District. § 531.033 requires access from a public street or alley in forward motion, for both entry and exit.
These rules apply only in unincorporated township areas of Franklin County.
Violations & Fines
A structure that doesn't provide the required loading spaces, or that sites one within 50 feet of a residential district, cannot receive a Certificate of Zoning Compliance from the county.
Frequently Asked Questions
What size building triggers the loading-space requirement?
How close can a loading space be to a home?
How many loading spaces does Franklin County require?
How big does each loading space have to be?
Sources & Official References
Other rules in Franklin County
Compare Franklin County to another location·View the Ohio parking rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.