Peoria County, IL Parking Rules: Loading Zones (2026)
Key Facts
- Governing section
- UDO § 7.7.15, Table 7-5
- Spaces at 25,001-40,000 sq ft
- 3 loading spaces required
- Minimum space size
- 12 by 35 or 50 feet
- Residential buffer for heavy loading
- 50 feet unless enclosed
- Enclosure wall height
- At least 6 feet, solid
- Telecom exemption
- No loading spaces required
Summary
Commercial buildings in Peoria County must provide off-street loading spaces sized by floor area under UDO Section 7.7.15 and Table 7-5, and any loading space serving vehicles over two tons must sit at least fifty feet from a residential district unless fully enclosed.
7.7.15 Number, Size and Location of Loading Spaces. The standards provided in this subsection are intended to provide an adequate size, number and design of loading spaces to serve the use proposed as well as avoid causing a nuisance for surrounding uses...2. No loading space for vehicles over two (2) tons capacity shall be closer than fifty (50) feet to any residential district, unless it is completely enclosed by either building walls or a uniformly painted solid fence or wall which is not less than six (6) feet in height.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 52).
Full Breakdown
Table 7-5, the Schedule of Loading Requirements, ties the number of required loading spaces directly to a building's floor area: one space for up to 10,000 square feet, two spaces from 10,001 to 25,000 square feet, three spaces from 25,001 to 40,000 square feet, four spaces from 40,001 to 100,000 square feet, and five spaces above 100,000 square feet, with one additional space required for every 50,000 square feet of floor area beyond 150,000. Each standard space must measure at least twelve feet by thirty-five feet up to the third tier and twelve by fifty feet above that, with a minimum fifteen-foot vertical clearance.
15 layers on siting standards: a loading space and its maneuvering area must sit entirely on the same lot as the use it serves, cannot be located in a public right-of-way, and must be oriented away from the street the lot fronts on. Loading spaces serving vehicles over two tons capacity cannot be closer than fifty feet to any residential district unless the loading area is fully enclosed by building walls or by a uniformly painted solid fence or wall at least six feet tall.
Recessed or sunken loading berths must include drainage so stormwater does not pond in the loading area for more than twenty-four hours after a storm ends, and telecommunications carrier facilities are exempt from providing loading spaces at all under item 8 of the same section.
Violations & Fines
Operating a commercial use without the loading spaces Table 7-5 requires, or locating a heavy-vehicle loading dock within fifty feet of a residential district without the required enclosure, is a UDO Section 10.2 violation. The Zoning Administrator can withhold occupancy or further permits for the property and, under Section 10.3, refer an uncorrected violation to circuit court for an order compelling compliance.
Frequently Asked Questions
How many loading spaces does my building need?
How close can a loading dock be to a house next door?
Do cell towers need loading spaces?
Sources & Official References
Other rules in Peoria County
Compare Peoria County to another location·View the Illinois parking rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.