Skip to main content
CityRuleLookup

Taylorsville, UT Accessory Structures: Shed & Carport Rules (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Shed permit rules in Taylorsville, UT, also referred to as storage shed, backyard shed, or accessory building regulations, set size limits, setbacks, and when a building permit is required.

Key Facts

Permit trigger
Over 200 sq ft or 2+ stories
By-right height (rear yard)
16 feet
Max single structure area
576 square feet
Setback from dwelling
6 feet minimum
Setback from property line
3 feet minimum
Conditional use height
Up to 20 feet

Summary

Taylorsville requires a building permit for any residential accessory structure over 200 square feet or more than one story. On lots under 15,000 square feet, a rear-yard shed built by right tops out at 16 feet tall, 576 square feet, and needs a 6-foot gap from the house and a 3-foot setback from the property line.

13.11.020: RESIDENTIAL ACCESSORY STRUCTURES: ... ... B. Building Permit Required: Any resident or property owner that desires to construct a residential or agricultural accessory structure that contains more than two hundred (200) square feet of floor area, or more than one story, shall submit a building permit application to the Taylorsville building department for consideration. ... ... E. Standards For Parcels Measuring Less Than Fifteen Thousand Square Feet: ... ... 1. Structures located in a rear yard of an interior lot (see figure 1 of this section): a. Allowed as a permitted use: (1) Maximum Height: Sixteen feet (16'). (2) Maximum Area: The maximum area for all accessory structures located in the rear yard combined shall be twenty five percent (25%) of the rear yard area. The maximum area for any one accessory structure shall be five hundred seventy six (576) square feet. (3) Setbacks (See Figure 2 Of This Section): (A) Accessory structures: Shall be a minimum of six feet (6') from a main building/dwelling. (B) Rear and side setbacks: Three feet (3') minimum from the accessory structure to the property line.

Full Breakdown

City Code Section 13.11.020(B) sets the permit trigger: any residential or agricultural accessory structure exceeding 200 square feet of floor area, or built more than one story, requires a building permit application to the Taylorsville building department, and all such structures must meet construction and fire-rating standards of the applicable codes. Section 13.11.020(E) then sets dimensional standards for parcels under 15,000 square feet. A shed placed in the rear yard of an interior lot is allowed by right up to 16 feet in height, with the combined footprint of all rear-yard accessory structures capped at 25 percent of the rear yard area and any single structure capped at 576 square feet.

It must sit at least 6 feet from the main dwelling and at least 3 feet from the property line, though anything closer than 5 feet to the line must still meet fire-rated wall standards under Section 13.11.020(D)(1). A homeowner who wants a taller or larger shed can seek an administrative conditional use permit, which raises the height ceiling to 20 feet but adds a design review of roof pitch, exterior colors, and materials for architectural compatibility with the main house. General rules layered on top of every accessory structure, regardless of size tier, bar separate utility meters, require storm drainage to stay on the same lot, and require any structure closer than 6 feet to another building to respect a 4-inch maximum eave encroachment into the setback.

Violations & Fines

Building or expanding an accessory structure without the required permit, or exceeding the height, area, or setback limits in Section 13.11.020, is enforced by the Taylorsville building department and Community Development, with violations prosecuted as a misdemeanor under City Code Section 1.08.020: up to six months in jail, a fine under $1,000, or both for an individual, and up to $5,000 for a corporation.

Frequently Asked Questions

Do I need a permit to build a shed in Taylorsville?
Yes, if it exceeds 200 square feet of floor area or has more than one story. City Code Section 13.11.020(B) requires a building permit application to the Taylorsville building department for any structure over that threshold.
How tall can my backyard shed be on a small Taylorsville lot?
On lots under 15,000 square feet, a rear-yard shed built as a permitted use is capped at 16 feet under Section 13.11.020(E)(1)(a); going to 20 feet requires an administrative conditional use permit with added design review.
How close to my property line can I build a shed?
Section 13.11.020(E)(1)(a)(3) sets a 3-foot minimum setback from the property line for a rear-yard shed, but anything within 5 feet of the line must meet fire-rated wall standards under Section 13.11.020(D)(1).

Sources & Official References

Other rules in Taylorsville

All Taylorsville rules

How Taylorsville compares: Shed Permit Requirements by City·Compare Taylorsville to another location·View the Utah accessory structures overview

Get notified when Shed & Carport Rules in Taylorsville, UT changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Shed & Carport Rules in Nearby Cities

How other cities in Salt Lake County handle shed & carport rules.

West Valley City, UT
Some Restrictions
South Jordan, UT
Some Restrictions
Sandy, UT
Some Restrictions
West Jordan, UT
Some Restrictions
Salt Lake City, UT
Some Restrictions