Fort Collins, CO Building Safety: Carbon Monoxide Detectors (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Trigger
Permitted alteration, repair, addition, or new bedroom
Standard applied
Same as required for new dwellings
Exceptions
Deleted by local amendment
Adopting ordinance
City Code Sec. 5-30
Code section
2024 IRC Sec. R311.2.2

Summary

Fort Collins requires carbon monoxide alarms to new-dwelling standards whenever a permitted alteration, repair, or addition occurs, or a bedroom is added, in an existing home, and the city strips out the model code's usual exceptions.

26.Section R311.2.2 Alterations, repairs and additions is amended to read as follows, with the exceptions being deleted in their entirety: R311.2.2 Alterations, repairs and additions. Where alterations, repairs or additions requiring a permit occur, or where one or more sleeping rooms are added or created in existing dwellings, the individual dwelling unit shall be equipped with carbon monoxide alarms located as required for new dwellings.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Municipal Code: Supplement 155 | Transitional Land Use Code (for project before May 17, 2024): Supplement 61 | Traffic Code: Supplement 27).

Full Breakdown

City Code Sec. 2, Alterations, repairs and additions, to require that where a permitted alteration, repair, or addition occurs, or where one or more sleeping rooms are added or created in an existing dwelling, the individual dwelling unit must be equipped with carbon monoxide alarms located exactly as required for new dwellings. Fort Collins goes further than the base model code by deleting the exceptions that would otherwise excuse certain smaller-scope work from the retrofit trigger, meaning any permitted alteration, repair, or addition project in the city brings the CO alarm requirement into play, not just larger-scope work.

4, Interconnection, which requires that where more than one smoke alarm is required within a dwelling unit, the devices must be interconnected so that one alarm activating triggers all alarms in the unit, with an exception for existing areas where interconnection would require removing interior wall or ceiling finishes without attic, crawlspace, or basement access. Together the two sections push retrofit projects toward the same alarm coverage and interconnection standard required in new construction. Compliance is verified by CDNS during the permit inspection tied to the triggering alteration, repair, addition, or bedroom-creation project; the alarms and their required locations follow the placement standards set for new dwellings elsewhere in the residential code's alarm sections.

Violations & Fines

Completing a permitted alteration, repair, addition, or new sleeping room without installing the required carbon monoxide alarms is a building code violation caught at final inspection; CDNS can refuse to sign off the permit and require alarm installation before the project is closed out or a certificate of occupancy issued.

Frequently Asked Questions

Does adding a bedroom to my Fort Collins home require a CO alarm?
Yes. Section R311.2.2 as amended requires carbon monoxide alarms to new-dwelling standards whenever one or more sleeping rooms are added or created in an existing dwelling, in addition to any permitted alteration, repair, or addition.
Are there exceptions to the CO alarm retrofit rule in Fort Collins?
No. The city's amendment to Section R311.2.2 deletes the exceptions that exist in the base International Residential Code, so any qualifying permitted work triggers the alarm requirement without the carve-outs found elsewhere.
Do multiple carbon monoxide or smoke alarms need to be interconnected?
Yes, under the related amended Section R310.4, where more than one smoke alarm is required in a dwelling unit, the alarms must be interconnected so activating one sounds all of them, with a limited exception for existing finished areas lacking attic or crawlspace access.

Sources & Official References

Other rules in Fort Collins

All Fort Collins rules

Compare Fort Collins to another location·View the Colorado building safety overview

Get notified when Carbon Monoxide Detectors in Fort Collins, CO changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Carbon Monoxide Detectors in Nearby Cities

How other cities in Larimer County handle carbon monoxide detectors.

Loveland, CO
Some Restrictions