Skip to main content
CityRuleLookup

Lacey, WA Building Safety: Carbon Monoxide Detectors (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

CO alarm standard (RVs)
NFPA 1192 Current Edition, Section 6.4.6
CO alarm standard (park trailers)
ANSI A119.5 Current Edition, Section 3-5
Applies to
RVs and recreational park trailers in manufactured home parks
Smoke detector
Also required, NFPA 1192 Section 6.3 or ANSI Section 3-3
Sleeping-area egress window
Minimum size of 24 x 17
Installation permit
Required from the city, fee set by city council

Summary

In the City of Lacey, Washington, the Lacey Municipal Code prints its own carbon monoxide alarm requirement for recreational vehicles and recreational park trailers installed in a manufactured home park. Each unit needs a working CO alarm installed to the NFPA 1192 or ANSI A119.5 section the code names, along with a working smoke detector and a sleeping-area exit.

G. Recreational park trailers and recreational vehicles may be installed within a manufactured home park if meeting the following requirements allowed by RCW 35A.21.312: 1. A working smoke detector shall be installed a. per NFPA 1192 Current Edition, Section 6.3 for recreational vehicles; or b. per ANSI A119.5 Current Edition, Section 3-3 for recreational park trailers; 2. A working carbon monoxide (CO) alarm shall be installed a. per NFPA 1192 Current Edition, Section 6.4.6 for recreational vehicles; or b. per ANSI A119.5 Current Edition, Section 3-5 for recreational park trailers; 3. There shall be egress directly from the sleeping area consisting of a door, or an egress window with a minimum size of 24 x 17 a. per NFPA 1192 2008 Edition, Section 6.2 for recreational vehicles; or b. per ANSI A119.5 Current Edition Section 3-2 for recreational park trailers;

Full Breakdown

LMC 14.14.025(G) is where the City of Lacey code addresses carbon monoxide alarms by name. It sits in Chapter 14.14, the manufactured home standards chapter, and covers recreational park trailers and recreational vehicles installed within a manufactured home park under RCW 35A.21.312. A working CO alarm must be installed per NFPA 1192 Current Edition, Section 6.4.6 for a recreational vehicle, or per ANSI A119.5 Current Edition, Section 3-5 for a recreational park trailer.

The CO alarm is one of eight conditions in the same subsection. The unit also needs a working smoke detector (NFPA 1192 Section 6.3 or ANSI A119.5 Section 3-3) and egress directly from the sleeping area through a door or an egress window with a minimum size of 24 x 17. The electrical cord must be protected within rigid conduit. The unit connects to the water supply and the sanitary sewer system provided within the park, under the adopted uniform plumbing code with all applicable fees paid. Steps, landings, stairways, decks and balconies must meet the International Residential Code and be independently supported. Each unit needs an internal toilet and internal shower, or the park must provide a common toilet and shower facility.

Installation also needs a permit. LMC 14.14.020 bars installing a recreational park trailer or recreational vehicle without complying with the adopted standards or without an installation permit from the city, issued after the owner or installer applies on city forms and pays a fee set by the city council. Under LMC 14.14.030 the city inspects each permitted installation and does not permit occupancy until inspection and approval are given.

This page covers only the carbon monoxide text printed in the Lacey Municipal Code. It does not quote requirements found in the codes the city adopts by reference.

Violations & Fines

Any violation of Chapter 14.14 or the standards adopted in it is a misdemeanor under LMC 14.14.050. Installing a recreational vehicle or recreational park trailer without complying with the standards or without the installation permit is barred by LMC 14.14.020, and the city withholds occupancy until it inspects and approves the installation under LMC 14.14.030. LMC 14.17.080 sets the Title 14 criminal maximum at a fine of up to $5,000 and/or imprisonment of up to one year.

Frequently Asked Questions

Does Lacey require a CO alarm in an RV in a manufactured home park?
Yes. LMC 14.14.025(G) requires a working carbon monoxide alarm in each recreational vehicle and recreational park trailer installed within a manufactured home park in the City of Lacey. For a recreational vehicle the standard is NFPA 1192 Current Edition, Section 6.4.6, and for a recreational park trailer it is ANSI A119.5 Current Edition, Section 3-5.
What else must be installed besides a CO alarm?
A working smoke detector, egress directly from the sleeping area through a door or an egress window with a minimum size of 24 x 17, and an electrical cord protected within rigid conduit. The unit also connects to the park's water and sanitary sewer with fees paid, and has an internal toilet and shower unless the park provides a common facility.
Does the City of Lacey inspect these installations?
Yes. LMC 14.14.030 directs the city to inspect the installation of each manufactured home, recreational park trailer or recreational vehicle covered by an installation permit, and the city does not permit occupancy until that inspection and approval have been given.
Who gets the installation permit and what does it cost?
The owner or installer applies on forms provided by the City of Lacey and pays a fee set by the city council. LMC 14.14.020 bars installation without that permit and without complying with the adopted standards, and any violation of Chapter 14.14 is a misdemeanor under LMC 14.14.050.

Sources & Official References

Other rules in Lacey

All Lacey rules

Compare Lacey to another location·View the Washington building safety overview

Get notified when Carbon Monoxide Detectors in Lacey, WA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.