Key Facts

Alarm placement
Outside each sleeping area, near bedrooms
Trigger
Fuel-fired appliance or attached garage
Existing homes
Required when permitted interior work occurs
Listing standard
UL 2034 single-station alarms

Summary

Meridian requires carbon monoxide alarms outside sleeping areas in new homes with fuel-fired appliances or attached garages, under its local IRC amendment.

Carbon Monoxide Alarms. For new construction, an approved carbon monoxide alarm shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms in dwelling units within which fuel-fired appliances are installed and in dwelling units that have attached garages.

D.A new section, section M1203.2, shall be added, to read as follows: Where Required In Existing Dwellings. Where interior work requiring a permit occurs in existing dwellings that have attached garages or in existing dwellings within which fuel-fired appliances exist, carbon monoxide alarms shall be provided in accordance with this section.

E.A new section, section M1203.3, shall be added, to read as follows: Alarm Requirements. Single station carbon monoxide alarms shall be listed as complying with UL 2034 and shall be installed in accordance with this code and the manufacturer's installation instructions.

F.A new sentence shall be added to section M1502.4.1, to read as follows: Material And Size. Dryer duct may be constructed of 0.013 (30 gage) or equivalent if prefabricated 0.016 (28 gage) ducts and fittings are not available.

G.Section M1502.4.2 shall be deleted, and replaced with language to read as follows:

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 14).

Full Breakdown

Meridian's amended Residential Code (IRC Part V, section M1203.1) requires an approved carbon monoxide alarm outside each separate sleeping area near bedrooms in any new dwelling unit that has fuel-fired appliances or an attached garage. Section M1203.2 extends the duty to existing dwellings undergoing permitted interior work. Alarms must be single-station units listed to UL 2034 and installed per the manufacturer's instructions under section M1203.3.

Violations & Fines

Violating this chapter is a misdemeanor under Meridian City Code § 10-5-6; each ten days a violation continues is a separate offense, and the city may also seek a civil injunction.

Frequently Asked Questions

Do older Meridian homes need a CO alarm?
Only when interior work requiring a permit is done on a home with an attached garage or fuel-fired appliances (§ M1203.2).
What counts as a trigger for the CO alarm rule?
Any fuel-fired appliance (like a gas furnace or water heater) or an attached garage in the dwelling unit.

Sources & Official References

Other rules in Meridian

All Meridian rules

Compare Meridian to another location·View the Idaho building safety overview

Get notified when Carbon Monoxide Detectors in Meridian, ID changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.