Skip to main content
CityRuleLookup

Morgan County, IN Building Safety: Electrical Permits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Adopted code
1959 National Electrical Code (NBFU #70)
Excluded areas
Martinsville and Mooresville
New home service minimum
100 amperes, 120/240V
Fine range
$10 to $300 per offense
Enforcing body
Morgan County Plan Commission

Summary

In unincorporated Morgan County, Indiana (Martinsville and Mooresville are excluded), all electrical wiring, installations and repairs must conform to the county's adopted 1959 National Electrical Code plus added local rules such as a 100-amp minimum service for new homes; violators face a misdemeanor fine.

These county ordinances apply to unincorporated areas of Morgan County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

All electrical wiring and all electrical installations and all repairs to either of the same in or upon any buildings, structures and premises in the county, except for the incorporated areas of Martinsville and Mooresville, shall conform to the requirements of this code and section. ... Conformity with the rules, regulations and standards prescribed in the September 1959 National Electrical Code published in November 1959 (NBFU #70) ... are hereby adopted as the electrical rules and regulations of this section which shall be prima facie evidence of conformity with approved standards for safety to life and property. ... Service entrance equipment for all new single and two-family residences where construction is started after effective date of this section shall be rated not less than 100 amperes. ... Any person, persons or corporations ... who violate any of the provisions of § 150.01, shall be guilty of a misdemeanor, and upon conviction, shall be fined not less than $10 and not more than $300 for each offense.

Full Breakdown

Morgan County Code § 150.01(A) requires all electrical wiring, installations and repairs on buildings, structures and premises in the county, other than the incorporated areas of Martinsville and Mooresville, to conform to the requirements of the section. Subsection (C) adopts by reference the rules, regulations and standards of the September 1959 National Electrical Code as published in November 1959 (NBFU #70), two copies of which are kept on file with the County Auditor for public inspection, as prima facie evidence of conformity with approved safety standards.

Subsection (D) layers on locally added rules: new single- and two-family residences begun after the section's effective date need service entrance equipment rated at least 100 amperes (100 amps, 120/240 volts, 3-wire, with a 100-amp main disconnect or breaker), trailers and non-residential occupancies need at least 60-amp service equipment (or 50 amps if breaker-controlled), 'BX' type cable is banned, and electric water heaters and clothes dryers must be wired with at least #10 AWG copper. The County Plan Commission administers enforcement and may sue for a mandatory injunction to remove a nonconforming electrical device.

Violations & Fines

Section 150.99(B) makes violating § 150.01 a misdemeanor punishable by a fine of not less than $10 and not more than $300 for each offense, with each day an improper electrical device remains in use counting as a separate offense. The County Plan Commission may also bring a mandatory injunction suit to force removal of a nonconforming device, and a successful Commission recovers its costs and reasonable attorney's fees from the respondent; the remedies are cumulative, not exclusive.

Frequently Asked Questions

Which electrical code does Morgan County use?
Section 150.01(C) adopts the September 1959 National Electrical Code as published in November 1959 (NBFU #70), with copies kept on file with the County Auditor, plus the county's own added rules in § 150.01(D).
Does the county electrical code apply inside Martinsville or Mooresville?
No. Section 150.01(A) expressly excludes the incorporated areas of Martinsville and Mooresville; the county's electrical rules apply only in unincorporated Morgan County.
What is the minimum electrical service for a new house in Morgan County?
Section 150.01(D)(1) requires new single- and two-family residences started after the section's effective date to have service entrance equipment rated at least 100 amperes, 120/240 volts, 3-wire, with a 100-amp main disconnect or breaker.

Sources & Official References

Other rules in Morgan County

All Morgan County rules

Compare Morgan County to another location·View the Indiana building safety overview

Get notified when Electrical Permits in Morgan County, IN changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.