Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Required stages
Foundation, slab, frame, lath, final
Inspection request notice
1 working day ahead
Inspecting official
Building official
Concealment rule
No covering work before approval
Reinspection fee
Charged if work not ready

Summary

Any Council Bluffs construction needing a permit must stay accessible for inspection by the building official under CBMC 13.01.305, which lists the required checkpoints: foundation, concrete slab or under-floor, frame, lath or wallboard, and a final inspection before occupancy. Work cannot proceed past an inspected stage until the official approves it.

General. Construction or work for which a permit is required shall be subject to inspection by the building official and the construction or work shall remain accessible and exposed for inspection purposes until approved by the building official. ... The building official, upon notification, shall make the ... following inspections: Foundation Inspection. To be made after excavations for footings are complete and required reinforcing steel is in place. ... Frame Inspection. To be made after the roof, framing, fire blocking and bracing are in place and all pipes, chimneys, and vents are complete and the rough electrical, plumbing, and heating wires, pipes, and ducts are approved. ... Final Inspection. To be made after finish grading and the building is completed and ready for occupancy.

Full Breakdown

CBMC 13.01.305 makes construction or work needing a permit subject to inspection by the building official, and the site must stay accessible and exposed until each stage is approved; certain work also gets continuous inspection under CBMC 13.01.306. The permit holder must post an inspection record card at the site and request each inspection, in writing or by phone, at least one working day ahead. Five inspections are named: a foundation inspection once footing excavation and reinforcing steel are in place and forms are set; a concrete slab or under-floor inspection before concrete or subfloor covers in-slab piping and conduit; a frame inspection once roof framing, fire blocking, bracing, and rough electrical, plumbing and heating work are in and complete; a lath or wallboard inspection before plaster or joint taping covers the wallboard; and a final inspection once grading is finished and the building is ready for occupancy.

Work cannot proceed beyond the point checked in each inspection without the building official's approval, and anything that fails must be corrected before it is covered or concealed. A reinspection fee applies under CBMC 13.01.305 when work is not ready at the time called, when the inspection card or approved plans are not on site, or when the site fails to match the approved plans, though the first rejection for simple noncompliance does not itself trigger the fee. Larger projects may also require a special inspector, employed by the owner or architect rather than the contractor, under CBMC 13.01.306, with a written inspection program approved before the permit issues.

Violations & Fines

Concealing framing, plumbing, electrical or fire-resistive work before the required inspection and approval violates CBMC 13.01.305 and CBMC 13.01.206's general prohibition on doing covered work contrary to the technical codes. The building official can require exposed work to be uncovered again for inspection at the responsible party's expense, and unreasonable reinspection requests draw the reinspection fee set in CBMC 13.01.304's fee tables.

Frequently Asked Questions

What inspections does Council Bluffs require during a home addition?
CBMC 13.01.305 lists a foundation inspection, a concrete slab or under-floor inspection, a frame inspection, a lath or wallboard inspection, and a final inspection, each covering the point in construction where that work would otherwise be hidden from view.
Can I cover up my framing before the Council Bluffs building official sees it?
No. CBMC 13.01.305 requires framing, including fire-blocking, bracing and any fire-resistive joints and penetrations, to stay exposed until the building official inspects and approves it; work may not proceed beyond an approved inspection point until that approval is given in writing or on site.
How much notice do I need to give for a building inspection in Council Bluffs?
CBMC 13.01.305 lets the building official require at least one working day's notice before an inspection, which may be requested in writing or by telephone, and the permit holder must keep an inspection record card posted and available at the job site.

Sources & Official References

Other rules in Council Bluffs

All Council Bluffs rules

Compare Council Bluffs to another location·View the Iowa building safety overview

Get notified when Building Inspections in Council Bluffs, IA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.