Key Facts

Adopted code
2018 International Plumbing Code with Town amendments
Permit applied to
The code official, before work starts
Irrigation systems
Residential and non-residential sprinklers need a permit
Minimum water service pipe
1 inch (25.4 mm) diameter
Drainage and vent air test
5 psi held not less than 15 minutes
Appeals body
Construction Board of Adjustments and Appeals

Summary

The Town of Collierville, Tennessee adopts the 2018 International Plumbing Code with local amendments. Any owner, authorized agent or contractor who installs, alters, repairs, removes or replaces a plumbing system, including residential and non-residential irrigation sprinkler systems, must first apply to the code official and obtain the required permit.

The following modifications and amendments to the 2018 International Plumbing Code (IPC) are hereby adopted: ... 106.1 Where required. ... Any owner, owner's authorized agent or contractor who desires to construct, enlarge, alter, repair, move, demolish or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any plumbing system (including residential and non-residential irrigation sprinkler systems), the installation of which is regulated by this code, or to cause any such work to be performed, shall first make application to the code official and obtain the required permit for the work. ... 603.1 Size of water service pipe. ... The water service pipe shall be sized to supply water to the structure in the quantities and at the pressures required in the Code. The minimum diameter of water service pipe shall be 1 inch (25.4 mm).

Full Breakdown

Section 150.050 of the Collierville Code of Ordinances adopts modifications and amendments to the 2018 International Plumbing Code (IPC). Wherever the IPC refers to the code official, it means the person appointed or designated by the municipal governing body to administer and enforce the Plumbing Code.

The local amendment to IPC Section 106.1, where required, is the permit trigger. Any owner, owner's authorized agent or contractor who wants to construct, enlarge, alter, repair, move, demolish or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any plumbing system, must first make application to the code official and obtain the required permit. The text expressly includes residential and non-residential irrigation sprinkler systems, so a lawn sprinkler installation needs a plumbing permit too. Irrigation components located in the public right-of-way or easements are installed at the owner's risk, and replacing or repairing them is the owner's responsibility if the easement or right-of-way is used.

The Town also changes several technical IPC provisions. The minimum diameter of water service pipe is 1 inch (25.4 mm). Building sewers must be a minimum of 12 inches below grade, and the drainage and vent air test is held at 5 psi for not less than 15 minutes. A reduced pressure backflow preventer must be tested and certified by an individual certified by the State of Tennessee, with test results on site at the time of inspection. Water distribution fittings are not placed under slab installations without prior approval from the Code Official.

Appeals of code official decisions go to the Town of Collierville Construction Board of Adjustments and Appeals under the local amendment to the means of appeal section.

Violations & Fines

Section 150.999 sets the penalty for violating any Town ordinance: a fine of not more than $50 or the maximum amount permitted by state law, whichever is greater, for each offense, with a separate offense deemed committed for each day of violation. Starting plumbing work without first applying to the code official and obtaining the permit falls under the permit requirement in IPC Section 106.1 as amended.

Frequently Asked Questions

Do I need a permit to install a lawn sprinkler system in Collierville?
Yes. The amended IPC Section 106.1 in Section 150.050 expressly covers residential and non-residential irrigation sprinkler systems. The owner, authorized agent or contractor must first make application to the code official and obtain the required permit for the work.
Who applies for the plumbing permit?
Any owner, owner's authorized agent or contractor who desires to do the regulated work, or to cause it to be performed, must make the application. The application goes to the code official, the person appointed or designated to administer and enforce the Plumbing Code.
What is the minimum water service pipe size in Collierville?
The amended Section 603.1 raises the minimum diameter of water service pipe to 1 inch (25.4 mm). The Town replaced the model code's smaller printed size, so plumbers working in the Town of Collierville design to the 1 inch minimum.
Where do I appeal a plumbing code decision?
The Town of Collierville Construction Board of Adjustments and Appeals hears appeals of orders, decisions or determinations by the code official regarding the application and interpretation of the code, under the local amendments to the 2018 International Codes adopted in Chapter 150.

Sources & Official References

Other rules in Collierville

All Collierville rules

Compare Collierville to another location·View the Tennessee building safety overview

Get notified when Plumbing Permits in Collierville, TN changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Plumbing Permits in Nearby Cities

How other cities in this county handle plumbing permits.

Memphis, TN
Some Restrictions