Skip to main content
CityRuleLookup

Tangipahoa Parish, LA Building Setbacks & Zoning: Setback Rules (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Governing law
Tangipahoa Parish Code § 36-111(a)
Front setback
25 feet minimum from property line
Subdivision entrance setback
35 feet on parish or state roads
Side/rear setback
10 feet minimum from property line
Zoning note
No zoning districts; setbacks apply uniformly parish-wide
Conflict rule
Most restrictive setback applies, per § 36-89(a)(4)

Summary

Because unincorporated Tangipahoa Parish has no zoning districts, yard setbacks come straight from the parish's subdivision and development standards rather than a zoning table. Section 36-111(a) sets a 25-foot front setback, a 35-foot setback for subdivision entrances on parish or state roads, and a ten-foot side and rear setback for undeveloped residential lots of record.

These county ordinances apply to unincorporated areas of Tangipahoa Parish. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

(a)Setbacks for residential lots. All undeveloped residential lots of record shall follow these setback requirements, unless otherwise specified in another section of this chapter or as noted on the recorded plat of existing approved subdivisions.(1)Front setback lines shall be a minimum of 25 feet from the property line.(2)A setback of 35 feet is required for the entrance to any residential subdivision fronting on a parish or state road.(3)Side and rear setback shall be ten feet from property lines.

Full Breakdown

Tangipahoa Parish has no parish-wide zoning districts, so there is no 'R-1' or 'R-2' setback table to consult. Instead, Chapter 36, 'Planning and Development,' fixes uniform minimum setbacks that apply directly to land in the unincorporated parish. Section 36-111(a), 'Setbacks for residential lots,' governs all undeveloped residential lots of record unless a different setback is written elsewhere in the chapter or noted on the recorded plat of an existing approved subdivision. It requires a front setback of at least 25 feet from the property line, a wider 35-foot setback where a residential subdivision entrance fronts a parish or state road, and a ten-foot side and rear setback.

The same ten-foot side and rear standard appears again in Section 36-89(c) for new subdivisions of land, and Section 36-90(a)(5) applies it to residential minor partitions (mini partitions), adding that their front setback is 25 feet from the public right-of-way line, or 18 inches behind the back slope of the drainage ditch where the right-of-way line cannot be determined. Manufactured and cargo-container homes follow an identical ten-foot side/rear, 25-foot front standard under Section 36-112(a)(3). Commercial buildings follow a separate, larger setback under Section 36-117: 25 feet side and rear, and 50 feet in front, each with its own ten- and 20-foot greenspace buffer strip.

Any structure built closer than these minimums to a lot line risks rejection at the parish permit office or a required survey correction before final plat approval.

Violations & Fines

The subdivision and development chapter is enforced through the parish's land clearing, plat and permit approval process rather than a standalone fine schedule for setback encroachments: a survey or final plat that does not meet Section 36-111(a)'s minimums will not receive planning department or planning commission approval, and Section 36-89(a)(4) directs that where any conflict between setback provisions arises, the most restrictive setback controls.

Frequently Asked Questions

Does Tangipahoa Parish have zoning districts with different setback rules?
No. Unincorporated Tangipahoa Parish has no parish-wide zoning districts, so setbacks are not divided by district. Section 36-111(a) applies one uniform standard, 25 feet front and 10 feet side and rear, to undeveloped residential lots of record across the unincorporated parish.
How close to my property line can I build in unincorporated Tangipahoa Parish?
Under Section 36-111(a), a residential structure must sit at least 25 feet back from the front property line and at least 10 feet back from the side and rear property lines, unless a different setback is noted on your subdivision's recorded plat.
What setback applies at a subdivision entrance?
Section 36-111(a)(2) requires a 35-foot setback for the entrance to any residential subdivision that fronts a parish or state road, which is wider than the standard 25-foot front setback applied to individual lots elsewhere in the subdivision, giving sight distance and turning room at the entry point.

Sources & Official References

Other rules in Tangipahoa Parish

All Tangipahoa Parish rules

Compare Tangipahoa Parish to another location·View the Louisiana building setbacks & zoning overview

Get notified when Setback Rules in Tangipahoa Parish, LA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.