Coconut Creek, FL Building Setbacks & Zoning: Structure Height Limits (2026)
Key Facts
- RM-10 apartments
- 4 stories or 40 feet
- RM-10 townhouses
- 2 stories or 35 feet
- RS-3, RS-4, RS-5 homes
- 25 feet
- A-1 and RS-1 homes
- 35 feet
- Yard increase
- 1 foot per 2 feet of height above 20 feet
- Governing section
- Coconut Creek Code § 13-338(d)(7)
Summary
In the City of Coconut Creek, Florida, the RM-10 district caps apartments at four stories or forty feet and townhouses at two stories or thirty-five feet. Single-family districts stop at 25 feet in RS-3, RS-4 and RS-5 and at 35 feet in A-1 and RS-1, and height above twenty feet enlarges side and rear yards.
(d)Development regulations. ... Development regulations for the RM-10 residential multiple-family district are as follows: ... (7)Maximum building height: Four (4) stories or forty (40) feet for apartments, two (2) stories or thirty-five (35) feet for townhouses;
Full Breakdown
Height in Coconut Creek is capped in feet, and in the multiple-family district in stories as well. Section 13-338(d)(7) sets the RM-10 maximum at four stories or forty feet for apartments and two stories or thirty-five feet for townhouses. Townhouse groupings in that district are also held to six units in a row for two-story units and eight for one-story units under (d)(13).
The single-family districts are lower. RS-3, RS-4 and RS-5 cap buildings at 25 feet (sections 13-334, 13-335 and 13-336.1), RC-5 at 25 feet (section 13-336.2), while A-1, RS-1 and RC-8 allow 35 feet (sections 13-332, 13-333 and 13-337). MH-1 caps a mobile home unit at 25 feet (section 13-340).
Height feeds back into setbacks. Under section 13-331(c)(2), rear and side yards grow by one foot for every two feet of height above twenty feet, and a building on a waterway adds one foot of distance from the water for every two feet over twenty under (c)(1). Section 13-331(h) exempts spires, belfries, minarets, cupolas and domes not used for human occupancy, and bridges, chimneys, ventilators, skylights, water tanks, bulkheads and similar features, along with necessary mechanical appurtenances carried above the roof such as elevator penthouses and air-conditioning equipment.
Violations & Fines
A structure built above the district maximum departs from section 13-331(a), which bars altering any building except in conformity with article III. The chapter's penalty clause in 13-331(j) points to the section 1-8 penalties and abatement by injunctive relief. Everything except one detached single-family dwelling on one lot also goes through site plan review under 13-331(i) before a building permit issues.
Frequently Asked Questions
How tall can a house be in an RS-4 neighborhood?
How tall can townhouses be in RM-10?
Do chimneys and rooftop equipment count against the height limit?
What is the height limit on an A-1 or RS-1 lot?
Sources & Official References
Other rules in Coconut Creek
Florida rules heatmap·Compare Coconut Creek to another location·View the Florida building setbacks & zoning overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Structure Height Limits in Nearby Cities
How other cities in Broward County handle structure height limits.