Coconut Creek, FL Building Setbacks & Zoning: Structure Height Limits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

RM-10 apartments
4 stories or 40 feet
RM-10 townhouses
2 stories or 35 feet
RS-3, RS-4, RS-5 homes
25 feet
A-1 and RS-1 homes
35 feet
Yard increase
1 foot per 2 feet of height above 20 feet
Governing section
Coconut Creek Code § 13-338(d)(7)

Summary

In the City of Coconut Creek, Florida, the RM-10 district caps apartments at four stories or forty feet and townhouses at two stories or thirty-five feet. Single-family districts stop at 25 feet in RS-3, RS-4 and RS-5 and at 35 feet in A-1 and RS-1, and height above twenty feet enlarges side and rear yards.

(d)Development regulations. ... Development regulations for the RM-10 residential multiple-family district are as follows: ... (7)Maximum building height: Four (4) stories or forty (40) feet for apartments, two (2) stories or thirty-five (35) feet for townhouses;

Full Breakdown

Height in Coconut Creek is capped in feet, and in the multiple-family district in stories as well. Section 13-338(d)(7) sets the RM-10 maximum at four stories or forty feet for apartments and two stories or thirty-five feet for townhouses. Townhouse groupings in that district are also held to six units in a row for two-story units and eight for one-story units under (d)(13).

The single-family districts are lower. RS-3, RS-4 and RS-5 cap buildings at 25 feet (sections 13-334, 13-335 and 13-336.1), RC-5 at 25 feet (section 13-336.2), while A-1, RS-1 and RC-8 allow 35 feet (sections 13-332, 13-333 and 13-337). MH-1 caps a mobile home unit at 25 feet (section 13-340).

Height feeds back into setbacks. Under section 13-331(c)(2), rear and side yards grow by one foot for every two feet of height above twenty feet, and a building on a waterway adds one foot of distance from the water for every two feet over twenty under (c)(1). Section 13-331(h) exempts spires, belfries, minarets, cupolas and domes not used for human occupancy, and bridges, chimneys, ventilators, skylights, water tanks, bulkheads and similar features, along with necessary mechanical appurtenances carried above the roof such as elevator penthouses and air-conditioning equipment.

Violations & Fines

A structure built above the district maximum departs from section 13-331(a), which bars altering any building except in conformity with article III. The chapter's penalty clause in 13-331(j) points to the section 1-8 penalties and abatement by injunctive relief. Everything except one detached single-family dwelling on one lot also goes through site plan review under 13-331(i) before a building permit issues.

Frequently Asked Questions

How tall can a house be in an RS-4 neighborhood?
Section 13-335(d)(8) sets the maximum building height in RS-4 at twenty-five feet. Under section 13-331(c)(2), rear and side yards also increase by one foot for every two feet of height above twenty feet, so a taller building pays for its height with wider yards.
How tall can townhouses be in RM-10?
Two stories or thirty-five feet under section 13-338(d)(7). Apartments in the same district can reach four stories or forty feet. The district also limits a grouping of two-story townhouses to six units in a row and one-story townhomes to eight, so height and length are both regulated.
Do chimneys and rooftop equipment count against the height limit?
No. Section 13-331(h) says the height limitations of the article do not apply to chimneys, ventilators, skylights, water tanks, bulkheads or similar features, or to necessary mechanical appurtenances usually carried above the roof level, such as elevator penthouses and air-conditioning equipment. Spires, belfries, minarets, cupolas and domes are exempt if not used for human occupancy.
What is the height limit on an A-1 or RS-1 lot?
Thirty-five feet. Section 13-332(d)(7) and section 13-333(d)(7) each set maximum building height at thirty-five feet for single-family detached homes. Those districts also require 50-foot front setbacks and two-acre or one-acre minimum lots, so the tall building sits well back from neighbors.

Sources & Official References

Other rules in Coconut Creek

All Coconut Creek rules

Florida rules heatmap·Compare Coconut Creek to another location·View the Florida building setbacks & zoning overview

Get notified when Structure Height Limits in Coconut Creek, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Structure Height Limits in Nearby Cities

How other cities in Broward County handle structure height limits.

Hollywood, FL
Some Restrictions
Pembroke Pines, FL
Some Restrictions
Miramar, FL
Some Restrictions
Pompano Beach, FL
Some Restrictions