6 rules for unincorporated Weber County, Utah.

Verified from official government sources

Note: These county rules apply to unincorporated areas of Weber County. If you live within an incorporated city, that city's own rules apply: see the city list below.

Fire Sprinkler Requirements

Weber County does not impose a blanket residential sprinkler mandate. Inside the county's Wildland Urban Interface area, its amended fire code lets the code official accept installed fire sprinklers as a substitute when a site has no available water supply capable of delivering fire flow, and lets sprinklered buildings be rated as a lower fire-hazard class.

Weber County WUI Fire Sprinkler Alternative

Light Restrictions

Weber County Code § 20-3-4

Sec 20-3-4 Revised Sections ... Add Section 404.11. No Available Water Supply. In areas where there is no available water supply, capable of supplying fire flow, as determined by the code official, fire sprinklers, as approved by the code official, may be considered as an alternative, as allowed under state law. In Section 602, remove the word "deleted" and add the following: "All structures de...

Childcare Center Rules

Weber County classifies a day care (child) center serving more than 50 students as a critical facility, the same tier as hospitals and fire stations, under Land Use Code § 101-2-8.020. That status bars the building from sitting astride an active fault, imposes a mandatory 50-foot fault setback, and requires a full geologic hazard study under §§ 108-22-2 and 108-22-3.

Weber County Day Care Center Fault-Zone Rules

Significant Restrictions

Weber County Land Use Code § 108-22-2

No critical facility (excluding transportation lines or utilities which by their nature may cross active faults) or structure designed for human occupancy shall be built astride an active fault. If a fault is discovered in the excavation for such a structure, a geologic hazard study and report, as provided in Section 108-22-3 of this Land Use Code, is required. ... Setbacks shall be a minimum o...

Carbon Monoxide Detectors

Weber County requires every licensed short-term rental to have working carbon monoxide detectors installed and maintained per the current building and fire codes, under the Section 108-11-8 fire safety operating standards enforced by the Planning Division.

Weber County: CO Detectors in Short-Term Rentals

Some Restrictions

Weber County Land Use Code § 108-11-8

Fire safety. ... Smoke and carbon monoxide detectors must be installed and maintained per current building and fire codes. Fire extinguishers must be placed in an approved location on each level of the property and adjacent to outdoor fire pits.

Building Permits

Weber County requires a permit before erecting, enlarging, altering, repairing, moving or demolishing any building or structure under Code § 12-3-1, which adopts the state's International Building Codes. Fees run on a valuation-based schedule, and building without a permit draws an added fee equal to the permit itself.

Weber County Building Permit Requirements

Some Restrictions

Weber County Code § 12-3-1

The specific editions of a nationally recognized code authority as adopted and amended by the State of Utah and published in Title 15A of the Utah Code, Chapter 2, Sections 103 and 104, are hereby adopted as the Building Code of Weber County, Utah, for regulating the erection, construction, enlargement, alteration, repair, moving, removal, demolition, conversion, occupancy, equipment, use, heig...

Plumbing Permits

Weber County requires a permit from the county plumbing inspector before plumbing tied to a public sewer connection can go in, and the work must comply with the International Plumbing Code as adopted by the county alongside the state-designated technical codes.

Weber County Plumbing Permit Requirement

Some Restrictions

Weber County Code § 36-1-2

no permits shall be issued for such sewer connections by the county plumbing inspector unless the plumbing and the building to be serviced shall comply with the requirements and regulations of the county and the state plumbing code (International Plumbing Code, 2009 Edition) and unless the applicant shall have complied with the requirements of the sewer district and paid the fees required for t...

Building Inspections

Weber County charges set fees for each building inspection stage under Code § 12-3-8: $115 to re-inspect failed work, $125 an hour for an after-hours inspection the county building official must approve, and a lapse fee once a permit goes 180 days without an inspection.

Weber County Building Inspection Fees, Process

Some Restrictions

Weber County Code § 12-3-8

1. In addition to the fee schedule in section 12-3-6: Electrical (excluding solar installations): $150.00. Plumbing: $100.00. Mechanical: $100.00. ... 3. Reinspection fee: $115.00. 4. Permit update fee. A $100.00 per year or any portion thereof, not to exceed $500.00, update fee will be charged when a permit goes more than 180 days without inspection unless the applicant can provide satisfactor...