Bloomington, IN Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Governing section
- UDO § 20.04.040(e)(4)(B)(ii)
- Freeboard amount
- 2 feet above base flood elevation (BFE)
- FPG definition
- BFE plus 2 feet in the SFHA
- Zone AO minimum
- 2 feet above highest adjacent grade if no depth mapped
- Applies to
- Lowest floor, including basement, of residential structures
Summary
New or substantially improved homes in a Bloomington special flood hazard area must have their lowest floor built at or above the Flood Protection Grade, defined as the base flood elevation plus two feet of freeboard, under Bloomington Municipal Code Section 20.04.040(e).
(ii)In Zone A and Zone AE. new construction or substantial improvement of any residential structure shall have the lowest floor; including basement, at or above the FPG. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with the standards of Section 20.04.040(e)(4)(C)(v). Should fill be used to elevate a structure, the standards of 20.04.040(e)(4)(C)(vi) must be met. ... "Flood Protection Grade (FPG)" means the BFE plus two feet at any given location in the SFHA. For sites within a SFHA designated as "Zone AO," the BFE is equivalent to the flood depth specified on the Flood Insurance Rate Map, measured from the highest adjacent grade. If no flood depth is specified, two feet is used as the minimum depth. (See "Freeboard") ... "Freeboard" means a factor of safety, usually expressed in feet above the BFE, which is applied for the purposes of floodplain management. It is used to compensate for the many unknown factors that could contribute to flood heights greater than those calculated for the base flood.
Full Breakdown
Bloomington's floodplain ordinance builds in an extra safety margin above FEMA's mapped base flood elevation (BFE) before it will let anyone build. The code defines the 'Flood Protection Grade' (FPG) as the BFE plus two feet at any location in a special flood hazard area; in a Zone AO area with no mapped flood depth, two feet above the highest adjacent grade is used as the minimum instead. That two-foot cushion is what the code calls 'freeboard,' a factor of safety applied because actual flood heights can exceed what the calculated base flood predicts.
040(e)(4)(B)(ii) applies that definition directly to houses: in Zone A and Zone AE, new construction or a substantial improvement of a residential structure must have its lowest floor, including any basement, at or above the FPG, meaning two feet above the mapped base flood elevation, not merely level with it. A builder who elevates the house on solid foundation perimeter walls must also install flood openings sized to let floodwaters move through the enclosed space automatically, and a builder who uses fill to reach that elevation has to meet separate fill-compaction and slope standards elsewhere in the same section.
Zone AH and Zone AO carry their own versions of the same two-foot-above-flood-depth rule. Anyone building new or adding a substantial improvement in one of Bloomington's mapped flood zones should plan the lowest floor elevation around the FPG number the Floodplain Administrator provides, not just the raw FEMA base flood elevation.
Violations & Fines
Building or substantially improving a residential structure below the Flood Protection Grade puts the project out of compliance with Section 20.04.040(e), which the ordinance's general penalty provision treats as a violation subject to common-nuisance enforcement, and it can also affect eligibility for a Standard Flood Insurance Policy on the property.
Frequently Asked Questions
How much freeboard does Bloomington require above base flood elevation?
Does the freeboard requirement include the basement?
What if my Bloomington lot is in Zone AO with no mapped flood depth?
Sources & Official References
Other rules in Bloomington
Compare Bloomington to another location·View the Indiana environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.