Bonneville County, ID Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard amount
- One foot above base flood elevation
- Applies to
- New residential and nonresidential construction
- Manufactured homes
- Lowest floor at flood protection elevation
- Floodproofing alternative
- Zones A, AE, AH, AO nonresidential only
- Certification required
- Registered engineer or architect
- Maximum penalty
- $500 fine, 180 days jail
Summary
Bonneville County adds a one-foot safety margin above the base flood elevation for construction in mapped flood hazard areas. Code § 154.02 defines freeboard and fixes it at one foot, and § 154.46 requires new residential construction to elevate its lowest floor no lower than that flood protection elevation.
FREEBOARD. A factor of safety usually expressed in feet above a flood level for the purposes of floodplain management. FREEBOARD tends to compensate for the many unknown factors that could contribute to flood heights greater than the height calculated for a selected size flood and floodway conditions, such as wave action, obstructed bridge openings, debris and ice jams, and the hydrologic effects of urbanization in a watershed. The base flood elevation (BFE) plus the freeboard establishes the flood protection elevation (FPE). FREEBOARD shall be one foot.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-1: Ordinance 280-26, passed 1-20-2026).
Full Breakdown
Section 154.02 defines FREEBOARD as 'a factor of safety usually expressed in feet above a flood level for the purposes of floodplain management,' meant to compensate for unknown factors such as wave action, obstructed bridge openings, debris and ice jams, and the hydrologic effects of urbanization that can push flood heights above the calculated base flood elevation. The same definition sets the number: the base flood elevation (BFE) plus the freeboard establishes the flood protection elevation (FPE), and freeboard shall be one foot.
Section 154.46 applies that flood protection elevation to construction standards in special flood hazard areas where BFE data exists. New construction or substantial improvement of a residential structure, including manufactured homes, tiny homes and park models, must have its lowest floor, including the basement, and its utilities and ductwork, elevated no lower than the flood protection elevation, meaning one foot above the mapped base flood elevation. Nonresidential construction faces the same elevation floor, but § 154.46(B) gives commercial, industrial and other nonresidential structures in Zones A, AE, AH and AO the option to floodproof to the flood protection elevation instead of physically elevating, provided the structure is watertight below that line and a registered engineer or architect certifies the floodproofing meets the standard. New or replacement manufactured homes must also be securely anchored to resist flotation and lateral movement, either through an engineered foundation or the state's manufactured home installation standard, with an engineering certification required once the chassis elevation exceeds 36 inches above grade.
Violations & Fines
Building below the required flood protection elevation, or altering a structure in a special flood hazard area without meeting the § 154.46 standards, violates Chapter 154 and is a misdemeanor under § 154.99: a fine of not more than $500, imprisonment of not more than 180 days, or both, with each day of noncompliance treated as its own separate offense.
Frequently Asked Questions
How much freeboard does Bonneville County require above the base flood elevation?
Where must the lowest floor of a new house sit in a flood hazard area?
Can a commercial building floodproof instead of elevating?
Sources & Official References
Other rules in Bonneville County
Compare Bonneville County to another location·View the Idaho environmental rules overview
See something wrong?