Bristol, PA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

Freeboard
1 1/2 feet above base flood elevation (§ 8-902)
Residential lowest floor
At or above regulatory flood elevation, basement included
Nonresidential option
Watertight floodproofing certified by engineer or architect
Flood openings
Two openings, one square inch per square foot enclosed
Unelevated accessory structure
Floor area not over 200 square feet
Fine
$100 to $600 plus costs, a misdemeanor
Administrator
Zoning Officer, Bristol Borough

Summary

In Bristol Borough, Pennsylvania, new construction and substantial improvement in the identified floodplain must put the lowest floor, basement included, at or above the regulatory flood elevation. Chapter 8 defines that elevation as the base flood elevation plus a freeboard safety factor of 1 1/2 feet. Nonresidential buildings can floodproof instead of elevating.

1. Residential Structures. A. In AE, A1-30, and AH Zones, any new construction or substantial improvement shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation. ... C. In AO Zones, any new construction or substantial improvement shall have the lowest floor (including basement) at or above the highest adjacent grade and at least as high as the depth number specified on the FIRM. ... 2. Nonresidential Structures. A. In AE, A1-30 and AH Zones, any new construction or substantial improvement of a nonresidential structure shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation or be designed and constructed so that the space enclosed below the regulatory flood elevation: (1) Is floodproofed so that the structure is watertight with walls substantially impermeable to the passage of water; and (2) Has structural components with the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy.

Full Breakdown

Section 8-502 sets the elevation rules for the Borough of Bristol floodplain. For a residential structure in AE, A1-30 and AH Zones, any new construction or substantial improvement needs the lowest floor, including the basement, elevated up to or above the regulatory flood elevation. Section 8-902 defines that term as the base flood elevation, or an estimated flood height from simplified methods, plus a freeboard safety factor of 1 1/2 feet. In A Zones where the FIRM shows no base flood elevation, the same standard applies using the elevation determined under § 8-402. In AO Zones the lowest floor must sit at or above the highest adjacent grade and at least as high as the depth number printed on the FIRM.

A nonresidential building in AE, A1-30 and AH Zones has a second option. Instead of elevating, the space below the regulatory flood elevation can be floodproofed so the structure is watertight, with walls substantially impermeable to water and components able to resist hydrostatic and hydrodynamic loads and buoyancy. Floodproofing follows the W1 or W2 classifications in the Army Corps of Engineers publication named in the code, and the plans carry a statement certified by a registered professional engineer or architect.

Fully enclosed space below the lowest floor, crawl spaces included, can be used only for parking, building access or incidental storage, and it needs openings that let floodwater in and out: at least two openings with a net total area of not less than one square inch for every square foot of enclosed space, the bottom of each no higher than one foot above grade. Accessory structures need not be elevated if floor area does not exceed 200 square feet, the structure is not used for habitation, and sanitary facilities and permanently affixed utility equipment are left out. A substantial improvement is one whose cost equals or exceeds 50% of the structure's market value before the start of construction. The Zoning Officer is the floodplain administrator, and § 8-302 requires a permit before any construction or development.

Violations & Fines

Section 8-310 has the floodplain administrator serve a written notice that states the reasons and allows a reasonable time, not to exceed 30 days, to comply. Failing to comply with Chapter 8 or with a notice is a misdemeanor, punishable by a fine to Bristol Borough of not less than $100 nor more than $600, plus costs of prosecution. The Borough also reserves other actions, including an action in equity, and paying a fine does not excuse the violation. Appeals from the administrator go to the Zoning Hearing Board within 30 days under § 8-311.

Frequently Asked Questions

How high must the lowest floor be in a Bristol Borough flood zone?
In AE, A1-30 and AH Zones the lowest floor, including any basement, must be elevated up to or above the regulatory flood elevation. The code defines that as the base flood elevation plus a freeboard safety factor of 1 1/2 feet. In AO Zones the floor must be at least as high as the depth number shown on the FIRM above the highest adjacent grade.
Can a commercial building floodproof instead of elevating in Bristol Borough?
Yes, in AE, A1-30 and AH Zones a nonresidential structure can be floodproofed below the regulatory flood elevation. The enclosed space must be watertight with walls substantially impermeable to water, and the structure must resist hydrostatic and hydrodynamic loads and buoyancy. The plans need a statement certified by a registered professional engineer or architect.
What openings does an enclosed space below the lowest floor need?
Fully enclosed space below the lowest floor, crawl spaces included, must let floodwater enter and exit automatically. Unless an engineer or architect certifies the design, it needs a minimum of two openings with a net total area of not less than one square inch per square foot of enclosed space, with the bottom of each opening no higher than one foot above grade.
Does a shed in the Bristol Borough floodplain have to be elevated?
An accessory structure need not be elevated or floodproofed if it meets the listed conditions. Floor area cannot exceed 200 square feet, it cannot be designed or used for human habitation, sanitary facilities are prohibited, and power lines, wiring and outlets must be elevated to the regulatory flood elevation. It must also be anchored and vented for floodwater.

Sources & Official References

Other rules in Bristol

All Bristol rules

Compare Bristol to another location·View the Pennsylvania environmental rules overview

Get notified when Flood Elevation Requirements in Bristol, PA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.