Decatur, GA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Residential freeboard
3 ft above base flood elevation
Alternative standard
1 ft above future-conditions elevation, if higher
Non-residential freeboard
1 ft above base flood elevation, or floodproof
Manufactured homes
3 ft elevation or 36-inch reinforced piers
Floodproofing certifier
licensed engineer or architect required
Governing section
UDO Sec. 9.5.6(B)

Summary

New homes and additions built in a Decatur, Georgia floodplain must sit at least three feet above the base flood elevation, or one foot above the future-conditions flood elevation if that figure is higher, under UDO Sec. 9.5.6.B.1. Non-residential buildings need only one foot of freeboard, or may floodproof instead.

New construction and substantial improvements of principal residential structures shall not be allowed within the limits of the future-conditions floodplain unless all requirements of Sec. 9.5.5.C., Sec. 9.5.5.D. and Sec. 9.5.5.E. have been met. If all of the requirements of Sec. 9.5.5.C., Sec. 9.5.5.D. and Sec. 9.5.5.E. have been met, all new construction and substantial improvements shall have the lowest floor, including basement, elevated no lower than three feet above the base flood elevation or one foot above the future-conditions flood elevation, whichever is higher.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 28).

Full Breakdown

UDO Sec. B sets separate freeboard standards by building type once the general floodplain development requirements of Sec. C, D and E are met. Principal residential structures, including manufactured homes under Sec. 5, must have their lowest floor, including any basement, elevated no lower than three feet above the base flood elevation, or one foot above the future-conditions flood elevation, whichever is higher; homes on existing manufactured home lots can instead rest on reinforced piers at least 36 inches above grade. Principal non-residential structures need only one foot of freeboard above the base flood elevation, or the future-conditions elevation if higher, under Sec.

2, and may floodproof to a watertight standard in lieu of elevating, provided a licensed engineer or architect certifies the design on a FEMA Flood-proofing Certificate. Sec. C applies the same three-foot residential and one-foot non-residential freeboard to buildings sited adjacent to, rather than inside, the future-conditions floodplain. Where solid perimeter walls are used to elevate a structure, Sec. 5 requires flood vents providing at least one square inch of net opening per square foot of enclosed area, with the lowest opening no higher than one foot above grade. Accessory structures permitted in the floodplain must use flood-resistant materials and the same venting standard.

Violations & Fines

Failing to meet the freeboard elevation or floodproofing certification requirement is enforced the same way as other Sec. 9.5 violations: a written notice of violation, then a stop-work order, withheld certificate of occupancy, or permit suspension, followed by civil penalties up to $1,000.00 per day and, for intentional or flagrant cases, a criminal citation carrying up to a $1,000.00 fine or 60 days in jail under Sec. 9.5.8.

Frequently Asked Questions

How high above flood level must a new Decatur, GA house be built?
UDO Sec. 9.5.6.B.1 requires the lowest floor, including basement, elevated no lower than three feet above the base flood elevation, or one foot above the future-conditions flood elevation, whichever figure is higher. Enclosures below that level must have flood vents sized under Sec. 9.5.6.A.5.
Is the freeboard requirement different for commercial buildings?
Yes. Sec. 9.5.6.B.2 sets a lower one-foot freeboard above the base flood elevation, or the future-conditions elevation if higher, for principal non-residential structures, and lets the owner floodproof to that same watertight standard instead of elevating, provided a licensed engineer or architect certifies the design.
What about manufactured homes in a Decatur floodplain?
Sec. 9.5.6.B.5 requires new and substantially improved manufactured homes to have their lowest floor elevated three feet above the base flood elevation or one foot above the future-conditions elevation, whichever is higher, or to rest on reinforced piers at least 36 inches above grade if placed in an existing manufactured home park.

Sources & Official References

Other rules in Decatur

All Decatur rules

Compare Decatur to another location·View the Georgia environmental rules overview

Get notified when Flood Elevation Requirements in Decatur, GA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.