Skip to main content
CityRuleLookup

Floyd County, GA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Governing law
Floyd County Code § 2-6-33(b)(1)
Freeboard
2 feet above base flood elevation
Utilities elevation
1 foot above base flood elevation
Fill clearance
At least 15 feet at building face
BFE defined
Floyd County Code § 2-6-35

Summary

New construction and substantial improvements in unincorporated Floyd County's special flood hazard areas must have their lowest floor elevated at least two feet above the base flood elevation, with heating, plumbing and electrical equipment raised at least one foot above it too.

These county ordinances apply to unincorporated areas of Floyd County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

(1)New construction and/or substantial improvements. Where base flood elevation data are available, new construction and/or substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, elevated no lower than two (2) feet above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate equalization of flood hydrostatic forces on both sides of exterior walls shall be provided in accordance with standards of subsection (a)(4), "Elevated buildings" of this section.a.All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other service facilities shall be elevated at or above one (1) foot above the base flood elevation. ... Base flood elevation (BFE). The elevation shown on the flood insurance rate map for zones AE, AH, A1-A30, AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO, V1-V30, and VE that indicates the water surface elevation resulting from a flood that has a one (1) percent chance of equaling or exceeding that level in any given year.

Full Breakdown

Section 2-6-33(b)(1) of the Floyd County Code sets the county's freeboard standard: where base flood elevation (BFE) data are available, new construction and substantial improvement of any structure or manufactured home must have the lowest floor, including any basement, elevated no lower than two feet above the base flood elevation. If solid foundation perimeter walls are used to elevate the structure instead of piers, the walls must include flood-vent openings sized to equalize hydrostatic forces on both sides, per the elevated buildings standard in subsection (a)(4).

Heating and air conditioning equipment, ductwork, electrical, ventilation and plumbing service facilities must be elevated at or above one foot above the base flood elevation. Sufficient fill must also be placed, where necessary, to provide at least 15 feet of clearance at ground surface between all faces of a dwelling and the base flood limits. Section 2-6-35 defines base flood elevation (BFE) as the elevation shown on the flood insurance rate map for zones AE, AH, A1-A30 and related designations that indicates the water surface elevation of a flood with a one percent annual chance of being equaled or exceeded.

Non-residential structures may floodproof instead of elevate, but must be watertight to two feet above the BFE under subsection (b)(2), certified by a registered engineer or architect.

Violations & Fines

Failure to meet the elevation or floodproofing standards of Section 2-6-33 is a violation of the flood damage prevention article under Section 2-6-31(h), punishable by a fine of up to $1,000.00, imprisonment for up to six months, or both, plus community service and case costs, with each day of continued noncompliance a separate offense.

Frequently Asked Questions

How high above the flood level does my new home need to be built?
Section 2-6-33(b)(1) requires the lowest floor, including any basement, to be elevated no lower than two feet above the base flood elevation for new construction and substantial improvements.
Does my HVAC and plumbing equipment need to be raised too?
Yes, Section 2-6-33(b)(1)(a) requires heating, air conditioning, electrical, ventilation and plumbing service facilities to be elevated at or above one foot above the base flood elevation.
What counts as the base flood elevation in Floyd County?
Section 2-6-35 defines base flood elevation as the water surface elevation shown on the flood insurance rate map for a flood with a one percent chance of being equaled or exceeded in any given year.

Sources & Official References

Other rules in Floyd County

All Floyd County rules

Compare Floyd County to another location·View the Georgia environmental rules overview

Get notified when Flood Elevation Requirements in Floyd County, GA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?