Key Facts

Freeboard requirement
100-year flood elevation plus 1.5 feet
Governing definition
§ 27-202, 'Regulatory Flood Elevation'
Elevation rule
§ 27-1305, Subsection 2.A
Nonresidential alternative
Floodproofing to W1/W2 Corps standards
Default minimum (no BFE data)
3 feet above highest adjacent grade
Enforcement
Floodplain Administrator; up to $500/day penalty

Summary

In Franklin Township, Chester County, Pennsylvania, new construction and substantial improvements in the Flood Hazard District must clear more than base flood elevation. Code § 27-202 defines the 'regulatory flood elevation' as the 100-year flood elevation plus a 1.5-foot freeboard safety factor, and § 27-1305 requires the lowest floor, including any basement, to sit at or above that elevated line.

REGULATORY FLOOD ELEVATION The 100-year flood elevation plus a freeboard safety factor of 1 1/2 feet. ... ... § 27-1305. Technical Provisions. ... ... 2. Elevation and Floodproofing Requirements. A. Residential Structures. (1) In AE, A1-30, and AH Zones, any new construction or substantial improvement shall have the lowest floor (including the basement) elevated up to, or above, the regulatory flood elevation.

Full Breakdown

Franklin Township builds a freeboard margin into its floodplain standards rather than stopping at FEMA's bare 100-year (base) flood elevation. The Code's definitions section, § 27-202, sets 'REGULATORY FLOOD ELEVATION' as the 100-year flood elevation plus a freeboard safety factor of 1 1/2 feet, and that elevated number, not the raw base flood elevation, is the line every Flood Hazard District project must clear. Section 27-1305, Technical Provisions, Subsection 2.A, applies the definition to residential construction: in AE, A1-30, and AH Zones, any new construction or substantial improvement must have its lowest floor, including the basement, elevated up to or above the regulatory flood elevation. In A Zones without mapped base flood elevations, the Township instead uses an elevation derived from the nearest floodplain boundary point under § 27-1304, Subsection 2.C, or, absent any usable data, a minimum of three feet above the highest adjacent grade.

Nonresidential buildings get an alternative under Subsection 2.B: elevate to the regulatory flood elevation or floodproof the space below it so the structure is watertight, with walls able to resist hydrostatic and hydrodynamic loads, following the Army Corps of Engineers' W1 or W2 floodproofing classifications, certified by a registered engineer or architect. Fully enclosed space below the lowest floor, other than a basement, must include flood vents equal to at least one square inch of opening per square foot of enclosed area, split across at least two walls, with openings no higher than one foot above grade. Both the 2009 International Building and Residential Codes and 34 Pa. Code Chapters 401-405 apply on top of these Township rules wherever they are stricter.

Violations & Fines

Building below the required regulatory flood elevation in Franklin Township's Flood Hazard District is a permit violation under §§ 27-1305 and 27-1303. The Floodplain Administrator can inspect construction, revoke a permit found out of compliance, and refer the matter to the Board of Supervisors; because Part 13 is part of the zoning chapter, the Code's general enforcement track in § 27-2304 also applies, exposing an owner to a civil judgment of up to $500 per day plus court costs.

Frequently Asked Questions

How high above flood level must a house be built in Franklin Township?
The lowest floor, including any basement, must sit at or above the 'regulatory flood elevation,' defined in § 27-202 as the 100-year flood elevation plus a freeboard safety factor of 1.5 feet, per § 27-1305, Subsection 2.A.
Can a nonresidential building be floodproofed instead of elevated?
Yes. Section 27-1305, Subsection 2.B lets nonresidential structures floodproof the space below the regulatory flood elevation instead of elevating it, provided the space is watertight and certified by a registered engineer or architect under Army Corps of Engineers W1 or W2 standards.
What if my lot has no mapped base flood elevation?
In A Zones without a mapped base flood elevation, § 27-1305, Subsection 2.A(2) points to the elevation method in § 27-1304, Subsection 2.C, or, lacking usable data, requires the lowest floor at least three feet above the highest adjacent grade.
What venting does an enclosed space below the flood line need?
Section 27-1305, Subsection 2.C requires at least two openings on separate walls totaling one square inch of net area per square foot of enclosed space, with the bottom of every opening no higher than one foot above grade.

Sources & Official References

Other rules in Franklin Township

All Franklin Township rules

Compare Franklin Township to another location·View the Pennsylvania environmental rules overview

Get notified when Flood Elevation Requirements in Franklin Township, PA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.