Skip to main content
CityRuleLookup

Grand Rapids, MI Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard
Base Flood Elevation plus 1 foot
Applies to
New construction in base flood areas
Certification
Registered land surveyor required
Waiver
City Manager, engineer-certified only

Summary

Grand Rapids bars new construction in flood-prone drainage areas from having a building opening below the Flood Protection Elevation, the base flood elevation plus one foot, under Chapter 32.

Any new construction or building undergoing substantial improvement in the base flood area of a swale, drainageway, floodway, ditch, culvert, or any other drainage facility or device shall strictly control the lowest building opening elevation so as to substantially limit flood damage to the building and its contents. Except as provided herein, no building opening shall be constructed below the following elevations: 1. Flood Protection Elevation. 2. The lowest building opening elevation established at the time of the plat or development approval.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 70).

Full Breakdown

Chapter 32, Section 2.213 requires that new construction or substantial improvement in the base flood area of a swale, drainageway, floodway, ditch, culvert or other drainage facility strictly control its lowest building opening elevation. No building opening may sit below the Flood Protection Elevation, defined in Section 2.203 as the Base Flood Elevation plus one foot, or the elevation set at the time of plat or development approval, whichever governs. A registered land surveyor must certify compliance before framing begins, and the City Manager can grant a waiver only on a Michigan-licensed engineer's written finding that the opening poses no flood hazard.

Violations & Fines

Building below the required opening elevation without a waiver violates Chapter 32; the City Manager can require the opening be raised and re-certified by a surveyor before framing continues.

Frequently Asked Questions

How much freeboard does Grand Rapids require above base flood elevation?
One foot: the code defines Flood Protection Elevation as the Base Flood Elevation plus one foot, and building openings can't sit below it.
Can I get a waiver from the freeboard rule?
Only if a Michigan-licensed engineer certifies in writing that the proposed opening elevation won't create a flood hazard, and the City Manager approves it.

Sources & Official References

Other rules in Grand Rapids

All Grand Rapids rules

Compare Grand Rapids to another location·View the Michigan environmental rules overview

Get notified when Flood Elevation Requirements in Grand Rapids, MI changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Kent County handle flood elevation requirements.

Wyoming, MI
Some Restrictions