Kingsport, TN Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- AE zone residential
- Lowest floor no lower than one foot above base flood elevation
- AE zone non-residential
- Elevate or floodproof to one foot above base flood elevation
- Approximate A zones
- Lowest floor at least three feet above highest adjacent grade
- AO zones
- FIRM depth number plus one foot of freeboard
- Enclosure openings
- Two openings, one square inch per square foot, bottoms within one foot of grade
- Certification
- Tennessee registered surveyor, engineer or architect (§ 114-265)
Summary
New construction and substantial improvements in a Kingsport special flood hazard area must put the lowest floor, including a basement, no lower than one foot above the base flood elevation in AE zones under § 114-268. Where FEMA has published no base flood elevation, the floor goes at least three feet above the highest adjacent grade. Non-residential buildings can floodproof instead of elevating.
(1)Residential structures. In AE zones where base flood elevation data is available, new construction and substantial improvement of any residential building (or manufactured home) shall have the lowest floor, including basement, elevated to no lower than one foot above the base flood elevation. ... Within approximate A zones where base flood elevations have not been established and where alternative data is not available, the administrator shall require the lowest floor of a building to be elevated to a level of at least three feet above the highest adjacent grade (as defined in subdivision II). ... (2)Non-residential structures. In AE zones, where base flood elevation data is available, new construction and substantial improvement of any commercial, industrial, or non-residential building, shall have the lowest floor, including basement, elevated or floodproofed to no lower than one foot above the level of the base flood elevation.
Full Breakdown
Section 114-268 sets the elevation standards for the City of Kingsport, Tennessee, in Division 5 of Chapter 114, and the city building official administers them. In AE zones with published base flood elevation data, a new or substantially improved residential building or manufactured home needs its lowest floor, basement included, elevated to no lower than one foot above the base flood elevation. The division defines freeboard as a factor of safety expressed in feet above a flood level, and the AO rule in § 114-272 labels its one-foot margin a freeboard.
Where the FIRM shows an approximate A zone with no base flood elevation and no alternative data, the administrator requires the lowest floor at least three feet above the highest adjacent grade. Non-residential buildings follow the same two numbers, but the owner can floodproof rather than elevate. A floodproofed building must be watertight below the required level, with walls substantially impermeable to water and structural components able to resist hydrostatic and hydrodynamic loads and buoyancy. A Tennessee registered professional engineer or architect must certify the design and give the certification to the administrator.
Shallow flooding zones carry their own numbers. In an AO zone the lowest floor must reach at least the depth number printed on the FIRM plus a freeboard of one foot above the highest adjacent grade, or at least three feet above the highest adjacent grade when the map shows no depth number (§ 114-272). Manufactured homes in an existing park in AE zones sit on a permanent foundation no lower than one foot above base flood elevation. In approximate A zones the chassis rides on reinforced piers at least three feet high above the highest adjacent grade.
Enclosures below the lowest floor are limited to parking, storage and building access. They need a minimum of two openings with a total net area of not less than one square inch for every square foot of enclosed area, and the bottom of every opening sits no higher than one foot above finished grade. When a building sits in more than one flood zone, or in a zone with several base flood elevations, the whole structure meets the standards for the most hazardous zone and the highest base flood elevation (§ 114-267).
Violations & Fines
Building below the required elevation violates Division 5 and is punishable under § 114-263 by a $50.00 penalty for each offense plus all costs and expenses, with a fine set by Tennessee statutes on top, and each day counts as a separate offense. The permit holder must file an as-built certification of the lowest floor elevation or floodproofing level once the lowest floor is complete. Work done before certification proceeds at the permit holder's risk, and failing to submit it or to correct deficiencies is cause for a stop-work order (§ 114-265). A variance to build below base flood elevation carries written notice of higher flood insurance premiums (§ 114-277).
Frequently Asked Questions
How high must I build above base flood elevation in Kingsport?
What if my Kingsport lot has no published base flood elevation?
Can a commercial building floodproof instead of elevating?
What rules apply to a garage or crawlspace below the lowest floor?
Sources & Official References
Other rules in Kingsport
Compare Kingsport to another location·View the Tennessee environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.