Skip to main content
CityRuleLookup

Kingsport, TN Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

AE zone residential
Lowest floor no lower than one foot above base flood elevation
AE zone non-residential
Elevate or floodproof to one foot above base flood elevation
Approximate A zones
Lowest floor at least three feet above highest adjacent grade
AO zones
FIRM depth number plus one foot of freeboard
Enclosure openings
Two openings, one square inch per square foot, bottoms within one foot of grade
Certification
Tennessee registered surveyor, engineer or architect (§ 114-265)

Summary

New construction and substantial improvements in a Kingsport special flood hazard area must put the lowest floor, including a basement, no lower than one foot above the base flood elevation in AE zones under § 114-268. Where FEMA has published no base flood elevation, the floor goes at least three feet above the highest adjacent grade. Non-residential buildings can floodproof instead of elevating.

(1)Residential structures. In AE zones where base flood elevation data is available, new construction and substantial improvement of any residential building (or manufactured home) shall have the lowest floor, including basement, elevated to no lower than one foot above the base flood elevation. ... Within approximate A zones where base flood elevations have not been established and where alternative data is not available, the administrator shall require the lowest floor of a building to be elevated to a level of at least three feet above the highest adjacent grade (as defined in subdivision II). ... (2)Non-residential structures. In AE zones, where base flood elevation data is available, new construction and substantial improvement of any commercial, industrial, or non-residential building, shall have the lowest floor, including basement, elevated or floodproofed to no lower than one foot above the level of the base flood elevation.

Full Breakdown

Section 114-268 sets the elevation standards for the City of Kingsport, Tennessee, in Division 5 of Chapter 114, and the city building official administers them. In AE zones with published base flood elevation data, a new or substantially improved residential building or manufactured home needs its lowest floor, basement included, elevated to no lower than one foot above the base flood elevation. The division defines freeboard as a factor of safety expressed in feet above a flood level, and the AO rule in § 114-272 labels its one-foot margin a freeboard.

Where the FIRM shows an approximate A zone with no base flood elevation and no alternative data, the administrator requires the lowest floor at least three feet above the highest adjacent grade. Non-residential buildings follow the same two numbers, but the owner can floodproof rather than elevate. A floodproofed building must be watertight below the required level, with walls substantially impermeable to water and structural components able to resist hydrostatic and hydrodynamic loads and buoyancy. A Tennessee registered professional engineer or architect must certify the design and give the certification to the administrator.

Shallow flooding zones carry their own numbers. In an AO zone the lowest floor must reach at least the depth number printed on the FIRM plus a freeboard of one foot above the highest adjacent grade, or at least three feet above the highest adjacent grade when the map shows no depth number (§ 114-272). Manufactured homes in an existing park in AE zones sit on a permanent foundation no lower than one foot above base flood elevation. In approximate A zones the chassis rides on reinforced piers at least three feet high above the highest adjacent grade.

Enclosures below the lowest floor are limited to parking, storage and building access. They need a minimum of two openings with a total net area of not less than one square inch for every square foot of enclosed area, and the bottom of every opening sits no higher than one foot above finished grade. When a building sits in more than one flood zone, or in a zone with several base flood elevations, the whole structure meets the standards for the most hazardous zone and the highest base flood elevation (§ 114-267).

Violations & Fines

Building below the required elevation violates Division 5 and is punishable under § 114-263 by a $50.00 penalty for each offense plus all costs and expenses, with a fine set by Tennessee statutes on top, and each day counts as a separate offense. The permit holder must file an as-built certification of the lowest floor elevation or floodproofing level once the lowest floor is complete. Work done before certification proceeds at the permit holder's risk, and failing to submit it or to correct deficiencies is cause for a stop-work order (§ 114-265). A variance to build below base flood elevation carries written notice of higher flood insurance premiums (§ 114-277).

Frequently Asked Questions

How high must I build above base flood elevation in Kingsport?
In AE zones with published data, § 114-268 puts the lowest floor of a residential building, basement included, no lower than one foot above the base flood elevation. A non-residential building meets the same one-foot mark by elevating or by floodproofing. The margin applies to new construction and to substantial improvements of existing buildings, which start at 50 percent of market value under § 114-255.
What if my Kingsport lot has no published base flood elevation?
In an approximate A zone with no base flood elevation and no alternative data, the administrator requires the lowest floor at least three feet above the highest adjacent grade. Under § 114-271, subdivisions and other developments larger than 50 lots or five acres, whichever is the lesser, must include base flood elevation data in their proposals.
Can a commercial building floodproof instead of elevating?
Yes, in all A zones, provided every area below the required elevation is watertight, with walls substantially impermeable to the passage of water and structural components that resist hydrostatic and hydrodynamic loads and buoyancy. A Tennessee registered professional engineer or architect must certify the design, and a FEMA floodproofing certificate goes in with the application under § 114-265.
What rules apply to a garage or crawlspace below the lowest floor?
Section 114-268 allows fully enclosed areas below the lowest floor only for parking of vehicles, storage or building access, with no finished living space. The design needs at least two openings totaling not less than one square inch per square foot of enclosed area, with bottoms no higher than one foot above finished grade, unless a Tennessee engineer or architect certifies another design.

Sources & Official References

Other rules in Kingsport

All Kingsport rules

Compare Kingsport to another location·View the Tennessee environmental rules overview

Get notified when Flood Elevation Requirements in Kingsport, TN changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?