Little Chute, WI Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

Freeboard required
2 feet above regional flood elevation
Fill standard
1 ft above flood level, 15-ft buffer
Governing article
Ch. 20, Art. IV, Floodfringe Districts
Basement rule
not allowed below regional flood elevation
Penalty
$10-$50 per day forfeiture

Summary

Little Chute requires new and substantially improved structures in the floodfringe district to have their lowest floor at or above the flood protection elevation, defined as two feet of freeboard above the regional flood elevation.

The elevation of the lowest floor, excluding the basement or crawlway, shall be at or above the flood protection elevation on fill. The fill shall be one foot or more above the regional flood elevation extending at least 15 feet beyond the limits of the structure.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 18 Update 1).

Full Breakdown

Under the village's floodplain zoning ordinance, adopted to comply with DNR and FEMA floodplain-management mandates, any habitable structure built, reconstructed, or moved into a mapped floodfringe area must have its lowest floor, excluding basement or crawlway, at or above the 'flood protection elevation': defined in Sec. 20-7 as two feet of freeboard above the regional or base flood elevation shown on the Outagamie County Flood Insurance Rate Map. The structure must sit on fill at least one foot above the regional flood elevation, extending 15 feet beyond the structure. Basements and crawlways may not go below the regional flood elevation at all. The zoning administrator enforces these standards village-wide within the mapped floodway, floodfringe, general floodplain, and flood storage districts.

Violations & Fines

A structure built below the required flood protection elevation without an approved variance is a Chapter 20 violation; the village prosecutes through the municipal attorney with forfeitures of $10 to $50 per day of continued violation.

Frequently Asked Questions

What is the 'flood protection elevation' in Little Chute?
It is two feet of freeboard above the water surface profile elevation set for the regional flood: the height a structure's lowest floor must meet or exceed in the floodfringe district under Sec. 20-89(1)a.
Does this freeboard rule apply outside the mapped floodplain?
No. It applies only within the village's mapped floodway, floodfringe, general floodplain, and flood storage districts under Chapter 20, based on the village's own adopted zoning map, not county zoning.

Sources & Official References

Other rules in Little Chute

All Little Chute rules

Compare Little Chute to another location·View the Wisconsin environmental rules overview

Get notified when Flood Elevation Requirements in Little Chute, WI changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Outagamie County handle flood elevation requirements.

Appleton, WI
Some Restrictions