Key Facts

Freeboard in AE, AH, A1-30 and A zones
Lowest floor at least one foot above base flood elevation
AO zones
One foot above FIRM depth number, or three feet if none
Certification
Registered civil engineer or surveyor, filed with floodplain administrator
Floodplain administrator
The city engineer
Flood insurance study date
August 4, 1988, with later amendments
Penalty
Misdemeanor

Summary

In National City, new residential construction and substantial improvements inside a mapped flood hazard area must set the lowest floor, basement included, at least one foot above the base flood elevation in AE, AH, A1-30 and unnumbered A zones. In AO zones the floor must clear the FIRM depth number by one foot, or sit three feet above the highest adjacent grade when no depth is shown.

a.Residential construction, new or substantial improvement, shall have the lowest floor, including basement:i.In an AO zone, elevated above the highest adjacent grade to a height exceeding the depth number specified in feet on the FIRM by at least one foot, or elevated at least three feet above the highest adjacent grade if no depth number is specified;ii.In an AE, AH, or A1—30 zones, elevated at least one foot above the base flood elevation, as determined by the city;iii.In an A (unnumbered/approximate A zone) zone, without base flood elevations specified on the FIRM, elevated at least one foot above the base flood elevation, as determined by the city; ... Upon the completion of the structure, the elevation of the lowest floor including basement shall be certified by a registered professional civil engineer or surveyor to be properly elevated. Such certification or verification shall be provided to the floodplain administrator.

Full Breakdown

The flood rules sit in § 18.29.070 of the National City Land Use Code (Title 18), the overlay chapter that creates the Floodway (FW) and Floodway Fringe (FF-1 through FF-4) zones. The chapter adopts by reference the Federal Emergency Management Agency flood insurance study for National City dated August 4, 1988, with its flood insurance rate maps, floodway maps and all later amendments. Those documents are kept at the floodplain administrator's office at 1243 National City Boulevard, and the city engineer holds the floodplain administrator job.

The elevation rule applies to new construction and substantial improvement. A substantial improvement is work whose cost equals or exceeds fifty percent of the structure's market value before the work starts, and substantial damage is measured the same way. Once the structure is finished, a registered professional civil engineer or surveyor certifies the lowest-floor elevation and the certification goes to the floodplain administrator.

Nonresidential buildings have a second route. They can meet the same elevation rule, or be completely flood-proofed so the walls are watertight and substantially impermeable, with structural components that resist hydrostatic and hydrodynamic loads and a civil engineer's certification. Fully enclosed areas below the lowest floor that serve only parking, building access or storage must either carry an engineer's certification or have at least two openings totaling not less than one square inch for every square foot of enclosed area, with the bottom of every opening no higher than one foot above adjacent natural grade.

In coastal high hazard zones (V, V1-30 and VE) the bottom of the lowest horizontal structural member must sit at or above the base flood level, on anchored pilings or columns. A development permit from the floodplain administrator is required before any building, grading or conditional use permit issues in a mapped area. Variances go to the planning commission, and anyone granted a variance to build below the base flood level receives written notice that flood insurance premium rates will rise. That notice is recorded with the San Diego County Recorder.

Violations & Fines

A violation of § 18.29.070, including breaking a condition or safeguard attached to a permit, is a misdemeanor, and the city can take whatever lawful action is needed to prevent or remedy it. A structure or development without the required elevation certificate or other proof of compliance is presumed to be in violation until the paperwork is produced. Building permits cannot issue on a conditional letter of map revision.

Frequently Asked Questions

How high must a new house in a National City flood zone be built?
In AE, AH and A1-30 zones the lowest floor, including any basement, must be at least one foot above the base flood elevation determined by the city. Unnumbered A zones follow the same one-foot rule. In AO zones the floor must exceed the FIRM depth number by at least one foot, or be three feet above the highest adjacent grade if no depth number is printed.
Who certifies the finished floor elevation?
Once the structure is complete, a registered professional civil engineer or surveyor certifies that the lowest floor, including basement, is properly elevated. The certification or verification is handed to the floodplain administrator, who under § 18.29.070 is the city engineer. The administrator records the actual elevation in relation to mean sea level for new or substantially improved structures.
Does a commercial building in National City have to be raised too?
A nonresidential building can be elevated to the same standard as a house, or it can be completely flood-proofed below the required elevation so the structure is watertight with walls substantially impermeable to water. The flood-proofing option needs structural components that resist hydrostatic and hydrodynamic loads and a registered professional civil engineer's certification provided to the floodplain administrator.
Can the planning commission grant a variance to build lower?
Variances are processed like conditional use permits and decided by the planning commission. The code requires good and sufficient cause, exceptional hardship and no increase in flood heights. Variances cannot issue in a mapped regulatory floodway if flood levels would rise. Recipients get written notice about higher flood insurance premiums and increased risk to life and property, recorded in the parcel's chain of title.

Sources & Official References

Other rules in National City

All National City rules

California rules heatmap·Compare National City to another location·View the California environmental rules overview

Get notified when Flood Elevation Requirements in National City, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in San Diego County handle flood elevation requirements.

Chula Vista, CA
Some Restrictions
Vista, CA
Some Restrictions
San Marcos, CA
Some Restrictions
San Diego, CA
Some Restrictions
Escondido, CA
Some Restrictions
Oceanside, CA
Some Restrictions
Carlsbad, CA
Some Restrictions
El Cajon, CA
Some Restrictions