Skip to main content
CityRuleLookup

Rockville, MD Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Residential freeboard
2 ft above base flood elev.
Critical facilities freeboard
1 ft (Sec. 10-75)
Electric panelboard
3 ft above BFE, Sec. 10-73(6)
Verified by
Licensed surveyor elevation cert.

Summary

New and substantially improved residential structures in Rockville's flood hazard areas must have their lowest floor at least two feet above the base flood elevation: the City's mandatory freeboard.

Lowest floors shall be elevated to or above the flood protection elevation (equal to two (2) feet higher than the base flood elevation).

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 17 Update 1).

Full Breakdown

Sec. 10-10 defines 'flood protection elevation' as the base flood elevation plus two vertical feet of freeboard, and Sec. 10-78(1)a. applies that number: residential lowest floors 'shall be elevated to or above the flood protection elevation.' Nonresidential structures follow the same two-foot standard, or may dry-floodproof to the base flood elevation plus one foot (Sec. 10-79). Critical and essential facilities get a separate, lower one-foot freeboard floor, or the 500-year flood elevation if higher (Sec. 10-75), and electric panelboards must sit at least three feet above base flood elevation (Sec. 10-73(6)). Compliance is documented through an elevation certificate a Maryland-licensed surveyor or engineer submits at the foundation stage and again before occupancy (Sec. 10-41).

Violations & Fines

Building below the required flood protection elevation without an approved floodplain variance violates Sec. 10-46 and Sec. 10-78, exposing the project to a stop-work order and administrative fines up to $1,000 per violation per day under Sec. 10-47.

Frequently Asked Questions

How high above the base flood elevation must a Rockville home be built?
At least 2 feet: the lowest floor must reach the 'flood protection elevation,' defined in Sec. 10-10 as base flood elevation plus 2 feet of freeboard.
Is the freeboard requirement different for critical facilities like fire stations?
Yes. Sec. 10-75 requires critical and essential facilities to hit base flood elevation plus 1 foot of freeboard, the building code elevation, or the 500-year flood elevation, whichever is highest.

Sources & Official References

Other rules in Rockville

All Rockville rules

Compare Rockville to another location·View the Maryland environmental rules overview

Get notified when Flood Elevation Requirements in Rockville, MD changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Montgomery County handle flood elevation requirements.

Gaithersburg, MD
Some Restrictions