Sampson County, NC Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Elevation floor
Reference level built no lower than Regulatory Flood Protection Elevation
Zone AO freeboard
FIRM depth number plus 2 feet, or 2 feet minimum
Small shed exemption
Accessory structures 600 sq ft or less can skip elevation
Utility rule
HVAC, water heaters, panels must sit at or above RFPE
Manufactured home threshold
Chassis over 36 inches needs engineering certification

Summary

Every new home and substantially improved structure in a Sampson County Special Flood Hazard Area must have its reference level, including the basement, built no lower than the Regulatory Flood Protection Elevation. Sec. 2-3-05.B(1) sets that floor for residential construction, and Sec. 2-3-05.A(4) requires HVAC, plumbing, and electrical equipment to sit at or above the same elevation.

These county ordinances apply to unincorporated areas of Sampson County. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

(4) All new electrical, heating, ventilation, plumbing, air conditioning equipment, duct systems, and other building utility systems, equipment, and service facilities shall be located at or above the Regulatory Flood Protection Elevation (RFPE) and/or specially designed to prevent water from entering or accumulating within the components and installed to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding to the design flood elevation. ... (1) Residential Construction. New construction and substantial improvement of any residential structure (including manufactured homes) shall have the reference level, including basement, elevated no lower than the Regulatory Flood Protection Elevation, as defined in Section 2-3-02 of this ordinance. The elevation requirements also apply to all new electrical, heating, ventilation, plumbing, air conditioning equipment and other service equipment.

Full Breakdown

Sec. 2-3-05.A(4) requires all new electrical, heating, ventilation, plumbing, and air conditioning equipment, along with water heaters, meter panels, and outlets, to be located at or above the Regulatory Flood Protection Elevation (RFPE), or specially designed to resist hydrostatic and hydrodynamic loads during flooding. Sec. 2-3-05.B(1) then sets the same RFPE floor for the reference level, including any basement, of new or substantially improved residential structures, including manufactured homes. Non-residential buildings in Zones A, AE, AH, AO, or A99 may floodproof to the RFPE instead of elevating, but a registered engineer or architect must certify the floodproofing under Sec.

2-3-05.B(2). Where FEMA has not mapped a Base Flood Elevation, Zone AO shallow-flooding areas get their own numeric standard under Sec. 2-3-05.G(1): the reference level must sit at least as high as the FIRM's printed depth number plus 2 feet of freeboard above the highest adjacent grade, or 2 feet above grade if no depth number is shown. Manufactured homes elevated more than 36 inches above grade on their chassis need an engineered foundation certification under Sec. 2-3-05.B(3)(b). A narrow carve-out in Sec. 2-3-05.B(8) lets accessory structures of 600 square feet or less in A, AO, AH, and AE zones skip the elevation and floodproofing standard if they are unheated, not used for living space, firmly anchored, and fitted with flood openings.

Violations & Fines

Building below the required elevation without an approved floodproofing certification breaks Sec. 2-3-05, and the Floodplain Administrator can deny the underlying Floodplain Development Permit outright over it. Because violating any provision of the Flood Damage Prevention Ordinance is a Class 1 misdemeanor under Sec. 2-3-03.H, the same construction can draw up to a $100 fine and 30 days in jail, and the county also withholds the Certificate of Compliance/Occupancy until a Finished Construction Elevation Certificate confirms compliance.

Frequently Asked Questions

How high must new construction be built in a Sampson County flood zone?
The reference level, including any basement, must be built no lower than the Regulatory Flood Protection Elevation for both residential and non-residential structures, under Sec. 2-3-05.B(1) and (2), with floodproofing allowed for non-residential buildings if a licensed engineer certifies it.
Do my AC unit and water heater have to meet the flood elevation rule too?
Yes. Sec. 2-3-05.A(4) requires all new electrical, heating, plumbing, and air conditioning equipment, along with meter panels and outlets, to sit at or above the Regulatory Flood Protection Elevation or be specially designed to keep water out.
Is my small storage shed exempt from the elevation rule?
An accessory structure of 600 square feet or less in Zones A, AO, AH, or AE can skip elevation and floodproofing under Sec. 2-3-05.B(8), but only if it is unheated, not used for living space, firmly anchored, and built with flood openings.
What if my property is in Zone AO with no mapped Base Flood Elevation?
Sec. 2-3-05.G(1) requires the reference level to sit at least as high as the FIRM's printed flood depth number plus 2 feet of freeboard above the highest adjacent grade, or at least 2 feet above grade if no depth number is shown.

Sources & Official References

Other rules in Sampson County

All Sampson County rules

Compare Sampson County to another location·View the North Carolina environmental rules overview

Get notified when Flood Elevation Requirements in Sampson County, NC changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.