Howard County, MD Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard, residential
- 2 ft above 100-yr flood elevation
- Freeboard, nonresidential
- 2 ft, or certified floodproofing
- New construction in floodplain
- barred, narrow exceptions only
- Certification required
- FEMA elevation cert. Form 086-0-33
- Governing code
- Howard County Building Code § 3115
Summary
Substantially improved homes and buildings in a Howard County floodplain must raise their lowest floor, including any basement, at least 2 feet above the 100-year flood elevation. Building Code Section 3115.3.1 sets that freeboard for residential structures, and Section 3115.3.2 lets nonresidential buildings floodproof instead, if every point below that elevation is watertight.
3115.3 Substantial improvements within a designated floodplain shall meet the standards set forth in this subsection and Title 16, Subtitle 7 of the Howard County Code. 3115.3.1. Residential. The lowest floor, including a basement, of substantial improvements to existing nonconforming residential structures located within a designated floodplain shall be elevated to at least 2 feet above the 100-year flood elevation. 3115.3.2. Nonresidential. The lowest floor, including a basement, of substantial improvements to existing nonconforming nonresidential structures shall be elevated to at least 2 feet above the 100-year flood elevation or shall be designed so that any area of the building which is lower than 2 feet above the 100-year flood elevation...is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of withstanding applicable hydrostatic, hydrodynamic, impact, soil, and, when applicable, hurricane and tidal wave loading conditions.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 91 | Zoning: Supplement 25).
Full Breakdown
Howard County's Building Code adds Section 3115, Floodplain, directly after the International Building Code's Section 3114, and Section 3115.3 sets the elevation standard for substantial improvements to existing nonconforming structures located within a designated floodplain. Section 3115.3.1 requires the lowest floor of a residential structure, basement included, to be elevated to at least 2 feet above the 100-year flood elevation, the county's freeboard margin above the base flood elevation used on FEMA's maps. Section 3115.3.2 gives nonresidential buildings an alternative: floodproof rather than elevate, provided any part of the building below that same 2-foot mark is watertight, with walls substantially impermeable to water and structural components able to withstand the hydrostatic, hydrodynamic, and, where relevant, hurricane and tidal-wave loads described in the Army Corps of Engineers' floodproofing standard and Section 16.705(c) of the County Code.
The Building Code treats new construction in a designated floodplain more strictly than substantial improvements: Section 3115.2.1 bars new residential or nonresidential construction from occurring within a designated floodplain at all, with narrow exceptions for a destroyed nonconforming structure rebuilt on the same footprint within 12 months, and for transportation, utility, and open-deck improvements approved by the Department of Public Works. Adjacent to, rather than within, a designated floodplain, Section 3115.5 applies the same 2-foot freeboard or floodproofing standard.
Elevation compliance is not optional paperwork. The floodproofing-by-elevation option requires the owner to submit a FEMA elevation certificate, Form 086-0-33, completed by a professional engineer or licensed Maryland land surveyor certifying the as-built lowest floor is elevated at least 2 feet above the 100-year floodplain elevation, filed before foundation approval by the Building Official.
Violations & Fines
A substantially improved structure whose lowest floor sits below the 2-foot freeboard mark, without an engineer-certified floodproofing alternative, fails Building Code Section 3115 inspection and cannot receive foundation approval from the Building Official. New construction placed inside a designated floodplain outside the narrow exceptions in Section 3115.2.1 is barred outright, and enforcement runs through the same floodplain permit and stop-work powers in Title 16, Subtitle 7 of the County Code.
Frequently Asked Questions
How high above flood level does my house have to be built in Howard County?
Can a business floodproof instead of elevating in a Howard County floodplain?
Can I build a brand-new house inside a Howard County floodplain?
Sources & Official References
Other rules in Howard County
Compare Howard County to another location·View the Maryland environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.