Skip to main content
CityRuleLookup

Shenandoah, TX Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Elevation standard
Lowest floor at or above base flood elevation
Who certifies
PE, architect or licensed land surveyor
Vent requirement
1 sq in vent per sq ft of enclosure
AO/AH zones
2 ft above grade if no depth listed
Penalty
Misdemeanor, up to $200 per day

Summary

Where FEMA has published a base flood elevation for the site, Shenandoah requires every new or substantially improved home to have its lowest floor, including any basement, built at or above that elevation. Section 86-132 of the Code of Ordinances puts the burden on a registered professional engineer, architect or land surveyor to certify compliance to the city's floodplain administrator before the project moves forward.

The following provisions shall be required in all areas of special flood hazards where base flood elevation data has been provided as set forth in section 86-37, subsection 86-77(8) or subsection 86-133(c): ... Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor, including basement, elevated to or above the base flood elevation. A registered professional engineer, architect or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection, as proposed in subsection 86-92(a)(1), is satisfied.

Full Breakdown

Chapter 86's flood hazard reduction division sets the technical floor for anything built in a mapped special flood hazard area once FEMA has assigned base flood elevation data (Sec. 86-37, Sec. 86-77(8) or Sec. 86-133(c)). General standards require all new construction and substantial improvements to be anchored against flotation and lateral movement, built with flood-damage-resistant materials, and designed so mechanical, electrical and plumbing equipment stays out of floodwaters (Sec. 86-131). The specific residential standard is blunt: the lowest floor, including a basement, of a new or substantially improved house must sit at or above the base flood elevation, certified by a registered professional engineer, architect or land surveyor (Sec.

86-132(1)). Nonresidential buildings get an alternative: floodproof the structure watertight below the base flood elevation, with a professional engineer certifying the design and a record of the specific floodproofed elevation kept by the floodplain administrator (Sec. 86-132(2)). Enclosed areas below the lowest floor used only for parking, building access or storage must have flood vents totaling at least one square inch of net opening per square foot of enclosed area, with the bottom of each opening no higher than one foot above grade (Sec. 86-132(3)).

Manufactured homes and recreational vehicles carry their own anchoring and elevation rules (Sec. 86-132(4)-(5)). In the shallower AO/AH flood zones, the elevation floor is instead the depth number printed on the FIRM, or at least two feet above the highest adjacent grade if no depth is shown (Sec. 86-134).

Violations & Fines

Section 86-42 makes any violation of the flood-hazard article a misdemeanor carrying a fine of up to $200.00 per day, and the city can seek injunctive relief and a civil penalty under V.T.C.A., Water Code Sec. 16.322. A home built below the required elevation without the engineer's certification can also be flagged during the as-built survey the floodplain administrator keeps on file and held up before occupancy.

Frequently Asked Questions

How high above the flood elevation must a new Shenandoah home be built?
At least to the base flood elevation itself; Section 86-132(1) requires the lowest floor, including any basement, of a new or substantially improved residential structure to be elevated to or above that FEMA-set number, verified by a registered professional engineer, architect or land surveyor before the floodplain administrator signs off.
What if my building is commercial, not residential?
Section 86-132(2) lets a nonresidential building floodproof instead of elevate, so long as the structure is watertight below the base flood elevation and a professional engineer certifies the design and materials can resist hydrostatic and hydrodynamic flood loads.
Are enclosed garages below the flood elevation allowed in Shenandoah?
Yes, if they are used only for parking, building access or storage and include flood vents equal to at least one square inch of net opening for every square foot of enclosed area, with the lowest opening no more than one foot above grade, per Section 86-132(3).
What is the elevation rule in a shallow AO or AH flood zone?
Section 86-134 sets the floor at whatever depth number is printed on the city's FIRM for that zone, or at least two feet above the highest adjacent grade if the map does not list a depth number.

Sources & Official References

Other rules in Shenandoah

All Shenandoah rules

Texas rules heatmap·Compare Shenandoah to another location·View the Texas environmental rules overview

Get notified when Flood Elevation Requirements in Shenandoah, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Montgomery County handle flood elevation requirements.

Conroe, TX
Some Restrictions