Conroe, TX Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard required
One foot above BFE
Governing section
Code sec. 78-82(1)
Permit
Floodplain development permit
Administrator
Director of Infrastructure Services
Penalty
Up to $500 per violation

Summary

New residential construction and substantial improvements in Conroe's FEMA special flood hazard areas must elevate the lowest floor, including any basement, to at least one foot above the base flood elevation, certified by a licensed engineer, architect, or surveyor before the floodplain administrator issues a permit.

Residential construction—New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), elevated to at least one foot above the base flood elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection as proposed in article IV, subsection 78-63(1)(a), is satisfied.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 85).

Full Breakdown

Conroe Code sec. 78-82(1) requires every new or substantially improved residential structure in a special flood hazard area to set its lowest floor at least one foot above the base flood elevation shown on the August 18, 2014 Montgomery County FIRM. Nonresidential buildings must match that one-foot freeboard or be dry-floodproofed to the same height. Electrical, heating, ventilation, plumbing, and air-conditioning equipment must also sit one foot above the base flood elevation. A floodplain development permit from the Director of Infrastructure Services (the floodplain administrator) is mandatory, and a registered engineer, architect, or land surveyor must certify the finished-floor elevation.

Violations & Fines

Building without full compliance is a misdemeanor. Each violation draws a fine of up to $500, plus all case costs, and the city council may pursue additional lawful action to remedy the noncompliant structure.

Frequently Asked Questions

How high must a new Conroe home be built in the floodplain?
The lowest floor, including any basement, must sit at least one foot above the base flood elevation mapped on the FEMA FIRM, per Conroe Code sec. 78-82(1).
Do I need a permit to build in a Conroe flood hazard area?
Yes. A floodplain development permit from the Director of Infrastructure Services is required, and an engineer, architect, or surveyor must certify the elevation (Code secs. 78-38, 78-82).
What about mechanical and electrical equipment?
HVAC, electrical, heating, and plumbing equipment must be at least one foot above the base flood elevation and located to prevent water entering during flooding (Code sec. 78-81(4)).

Sources & Official References

Other rules in Conroe

All Conroe rules

Texas rules heatmap·Compare Conroe to another location·View the Texas environmental rules overview

Get notified when Flood Elevation Requirements in Conroe, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Montgomery County handle flood elevation requirements.

Shenandoah, TX
Some Restrictions