York County, VA Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard, AE/AH residential
- 3 feet above base flood elevation
- Coastal AE (LiMWA) freeboard
- 4 feet above base flood elevation
- Zone AO minimum
- 2 feet above highest adjacent grade
- Flood vent opening
- 1 sq in per sq ft, 2 sides minimum
- Non-residential option
- Floodproofing to BFE plus 1 foot
Summary
In York County, Virginia, new residential construction and substantial improvements in the AE and AH flood zones must have the lowest floor, including any basement, elevated with at least three feet of freeboard above the base flood elevation, or the building must be fully floodproofed if non-residential.
All new construction or substantial improvement in Zone AE and AH of the floodplain management area shall occur in accordance with the applicable floodplain construction provisions for Zone AE and AH contained in the Virginia Uniform Statewide Building Code. ... c.The elevation of the lowest floor of any residential structure, including basements, shall be constructed with a freeboard at least three feet (3') above the base flood elevation. Non-residential structures may be flood-proofed in lieu of being elevated, provided that all areas of the building components below the elevation corresponding to the BFE plus one foot are water tight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy.
Full Breakdown
Sec. 24.1-373(e)(9) sets the construction standards for Zone AE and AH, the areas where FEMA has mapped detailed base flood elevations. New construction and substantial improvements must follow the Virginia Uniform Statewide Building Code's floodplain provisions, and the Floodplain Administrator must confirm compliance before issuing building permits or certificates of occupancy. The lowest floor of any residential structure, including a basement, must carry a freeboard of at least three feet above the base flood elevation; non-residential buildings may be floodproofed instead, provided everything below the base flood elevation plus one foot is watertight and can resist hydrostatic and hydrodynamic loads, certified by a registered engineer or architect.
Electrical equipment, heating and cooling systems, and electrical distribution panels must also sit at least three feet above the base flood elevation. Coastal AE zones within the Limits of Moderate Wave Action, subject to 1.5-3 foot wave heights, must add one more foot for four feet of total freeboard. In Zone AO, where flood depths rather than elevations are mapped, the lowest floor must be elevated to the mapped depth number plus freeboard, or at least two feet above the highest adjacent grade if no depth number is shown.
Any enclosed area below the lowest floor in Zones A, AE, AH, or AO can only be used for parking, building access, or storage, must use flood-resistant materials, and needs flood vents totaling at least one square inch of net opening per square foot of enclosed area, with openings on at least two different sides.
Violations & Fines
Enforcement of Sec. 24.1-373 runs through Sec. 24.1-109 and Article VI of Chapter 7.1, Building Regulations. A structure without the required elevation certificate or engineer's certification is presumed noncompliant until the documentation is filed, and the Floodplain Administrator can issue notices of violation or stop-work orders and require corrective action.
Frequently Asked Questions
How much freeboard does York County require above base flood elevation?
Can a commercial building be floodproofed instead of elevated?
What are the rules for enclosed space below an elevated floor?
Does Zone AO have different elevation rules than AE?
Sources & Official References
Other rules in York County
Compare York County to another location·View the Virginia environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.