Scranton, PA Fire Regulations: Smoke Detectors (2026)
Key Facts
- Governing section
- § 243-4D (amends F-503.4)
- Every story
- Detector required, basements included
- R-1/R-2/I-1
- Detector in every guest room/corridor
- Penalty
- $200-$600 fine or 30 days jail
- Appeal window
- 10 days to Dept. of Public Safety
Summary
Scranton's Fire Prevention Code requires smoke detectors on every story of every dwelling unit, including basements, and in each guest room, suite and corridor of hotels, dormitories and similar occupancies. The rule, City Code § 243-4D, amends the adopted 1999 BOCA National Fire Prevention Code section F-503.4 and applies citywide to residential and lodging occupancies inspected by the Bureau of Fire Prevention.
F-503.4 Single- and multiple-station smoke detectors: Single- and multiple-station smoke detectors shall be installed in each guest room, suite, sleeping area and corridor in Use Groups R-1, R-2 and I-1 and in dwelling units in the immediate vicinity of the bedrooms in occupancies in Use Group R-3. In all residential occupancies, smoke detectors shall be required on every story of the dwelling unit, including basements. In dwelling units with split levels and without an intervening door between the adjacent levels, a smoke detector installed on the upper level shall suffice for the adjacent lower level, provided that the lower level is less than one full story below the upper level.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4719898; v25 updated 2025-12-16; through 12-16-2025).
Full Breakdown
The City of Scranton adopted the 1999 BOCA National Fire Prevention Code as its Fire Prevention Code under § 243-1, then amended several of its sections, including the smoke detector rule, under § 243-4. 4 requires single- and multiple-station smoke detectors in each guest room, suite, sleeping area and corridor of Use Groups R-1 (hotels, motels), R-2 (apartments, dormitories) and I-1 (institutional occupancies such as assisted living), and in the dwelling units of Use Group R-3 (one- and two-family homes) in the immediate vicinity of the bedrooms.
Beyond the room-by-room rule, the ordinance requires a detector on every story of a residential dwelling unit, including the basement, regardless of whether that story contains a bedroom. Split-level homes get a narrow exception: where there is no door separating the levels and the lower level sits less than a full story below the upper one, a single detector on the upper level can serve both. Permits and inspections under this chapter run through the Fire Chief and the chief fire inspector; a property owner who disputes a Fire Chief decision, or believes the code was misapplied, has 10 days from the decision to appeal to the Director of the Department of Public Safety under § 243-2. 4 language was inserted by Ordinance No. 61-1999, adopted April 26, 1999.
Violations & Fines
Violating any provision of the Fire Prevention Code, including the smoke detector requirement, is a summary offense under amended § F-112.3 (§ 243-4C): a fine of not less than $200 and not more than $600 plus costs, or up to 30 days in jail if the fine is unpaid. Each day the violation continues counts as a separate offense, and the violator remains responsible for the cost of bringing the property into compliance.
Frequently Asked Questions
Does Scranton require smoke detectors in basements?
What happens if my rental doesn't have working smoke detectors?
Do split-level homes need a detector on every level?
Can I appeal if a fire inspector cites my property?
Sources & Official References
Other rules in Scranton
Compare Scranton to another location·View the Pennsylvania fire regulations overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.