Waukegan, IL Fire Regulations: Smoke Detectors (2026)
Key Facts
- Governing section
- City Code § 9-109.1(6)
- Applies to
- Licensed day-care homes in 1-2 unit dwellings
- Alarm type
- Hardwired and interconnected
- Minimum coverage
- One alarm per occupied level
- Enforced by
- Waukegan Fire Department
- Base code
- NFPA 101 Life Safety Code, 2015 Ed.
Summary
Waukegan's Life Safety Code amendments require every licensed family or group day-care home inside a one- or two-family dwelling to install smoke alarms wired to the building's electrical system, arranged so one alarm sounding trips every alarm in the home. City Code § 9-109.1(6) mandates at least one alarm on each occupied level, excluding attics and crawl spaces.
(6)The home shall be equipped with smoke alarms permanently powered by the building's electrical system and wired so that the actuation of one smoke alarm will actuate all the smoke alarms in the dwelling. At least one such smoke alarm shall be located on each level of the occupancy (excluding unoccupied attics and crawl spaces), and the path of escape through the level of exit discharge (from the basement door to the exterior of the home) must be protected by automatic fire sprinklers. Listed residential sprinklers shall be used and the installation shall be made in accordance with the applicable Codes. ... 16.6.3.4.2 shall have new additional language added to end of section: "Or a smoke alarm system complying with the following requirements: i) Smoke alarms connected to the building's electric shall be installed in accordance with proper coverage standards in the corridor serving the day care home, ii) Smoke alarms connected to the building's electric shall be installed in accordance with the proper coverage standards within the daycare home (See section 16.6.3.4)."
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 113).
Full Breakdown
1. 5 for new and existing day-care occupancies, requires a day-care home located within a one- or two-family dwelling to have smoke alarms permanently wired to the building's electrical system and interconnected so any one alarm sounding actuates all alarms in the dwelling. At least one alarm is required on every occupied level, excluding unoccupied attics and crawl spaces. Where the escape path runs through the level of exit discharge, from a basement door to the exterior, that path must also be protected by listed automatic residential fire sprinklers installed per applicable codes.
2 let a facility instead install a smoke alarm system covering both the corridor serving the day-care home and its interior, with alarms in either area triggering all alarms in both. 4. Three copies of the amended 2015 NFPA 101 Code are kept on file with the city clerk for public inspection.
Violations & Fines
Section 9-109.1 sets no separate fine schedule for a missing or non-interconnected smoke alarm; a day-care home found out of compliance during a Waukegan Fire Department life-safety inspection is enforced through the general penalty, City Code § 1-13, $25.00 to $750.00 per offense, with each day of continued noncompliance treated as a separate violation.
Frequently Asked Questions
Does Waukegan require smoke alarms in day-care homes?
How many smoke alarms does a day-care home need?
Who inspects day-care homes for smoke alarm compliance?
Is there an alternative to hardwired interconnected alarms?
Sources & Official References
Other rules in Waukegan
Compare Waukegan to another location·View the Illinois fire regulations overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.