Terrebonne Parish, LA Hurricane Preparedness: Flood Elevation (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Zone
Coastal high hazard areas V1-30, VE, V
Elevation method
Pilings or columns to 2021 IBC minimum
Breakaway wall load
10 to 20 lbs per sq ft design
Fill for support
Prohibited outright
Dune/mangrove alteration
Prohibited
Enclosed space use
Parking, access, storage only, no habitation

Summary

In Terrebonne Parish's coastal high hazard zones (V1-30, VE, V), the Gulf-exposed areas most at risk from hurricane storm surge and wave wash, new construction and substantial improvements must be elevated on pilings or columns to or above the 2021 IBC minimum. Breakaway walls, fill bans, and dune protections under Sec. 9-60 add hurricane-specific standards on top of the parish's general flood elevation rule.

These county ordinances apply to unincorporated areas of Terrebonne Parish. Incorporated cities within the county may have their own rules that take precedence over county-level regulations.

Located within the SFHA established in section 9-8 are areas designated as coastal high hazard areas (zones V1-30, VE, and/or V). These areas have special flood hazards associated with high velocity waters from tidal surges and hurricane wave wash; therefore, in addition to meeting all provisions outlined in this chapter, the following provisions must also apply: ... (3)All new construction and substantial improvements shall be elevated on pilings and columns so that:a.The bottom of the lowest horizontal structural member of the lowest floor (excluding the pilings or columns) is elevated to or above the minimum elevation required by the effective building code (IBC 2021 as amended); and

Full Breakdown

Sec. 9-60 covers the coastal high hazard areas within Terrebonne Parish's special flood hazard zones, mapped as zones V1-30, VE, and V, which the code describes as subject to high velocity waters from tidal surges and hurricane wave wash. On top of every other Chapter 9 requirement, new construction and substantial improvements there must be elevated on pilings and columns so the bottom of the lowest horizontal structural member of the lowest floor sits at or above the minimum elevation required by the effective building code, the 2021 IBC as amended, with the piling or column foundation anchored to resist flotation, collapse, and lateral movement from combined wind and water loads.

A registered professional engineer or architect must certify the design. Space below the elevated floor has to stay open or use breakaway walls, open lattice, or insect screening rated to collapse under wind and water loads without damaging the structure above; a breakaway wall's design load has to fall between ten and twenty pounds per square foot unless an engineer certifies a higher-rated design that will still fail before the base flood load hits the elevated structure. Filling for structural support of buildings is banned outright, as is manmade alteration of sand dunes and mangrove stands that would raise flood damage potential.

Enclosed space below the lowest floor can only be used for vehicle parking, building access, or storage, never for human habitation, and any plans involving breakaway walls have to go to the floodplain administrator for approval before construction starts.

Violations & Fines

Coastal high hazard construction that skips the piling elevation, uses fill for structural support, or alters protected dunes and mangroves is enforced through the same Chapter 9 process as any other flood violation: the floodplain administrator issues certified-mail notice under Sec. 9-2 with a window to correct, and noncompliance is punishable as a misdemeanor, with each day counted as a separate offense.

Frequently Asked Questions

What's different about building in Terrebonne Parish's coastal flood zones versus the regular flood zones?
Sec. 9-60 adds hurricane-specific rules for zones V1-30, VE, and V, the areas exposed to tidal surge and hurricane wave wash. Structures there must sit on pilings or columns rather than fill, fill cannot be used for structural support at all, and any enclosed space below the elevated floor must use breakaway walls engineered to fail before the base flood hits.
How strong do breakaway walls have to be?
Sec. 9-60 sets a design safe loading resistance of ten to twenty pounds per square foot. A higher-rated wall is only allowed if a registered professional engineer or architect certifies it will still collapse before a water load equal to the base flood and won't damage the elevated structure above it.
Can I fill in the ground to raise my coastal lot instead of building on pilings?
No. Sec. 9-60(5) prohibits using fill for the structural support of buildings in coastal high hazard areas, and manmade alteration of sand dunes or mangrove stands that would increase flood damage potential is barred as well under the same section.

Sources & Official References

Other rules in Terrebonne Parish

All Terrebonne Parish rules

Compare Terrebonne Parish to another location·View the Louisiana hurricane preparedness overview

Get notified when Flood Elevation in Terrebonne Parish, LA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.