Wellington, FL Hurricane Preparedness: Flood Elevation (2026)
Key Facts
- Elevation standard
- FBC Residential R322.2 (Zone A)
- Anchoring
- Over-the-top or frame ties required
- Floodway ban
- No manufactured homes in floodways
- Installer
- Licensed under F.S. § 320.8249
Summary
Manufactured homes placed, replaced or substantially improved in a Wellington flood hazard area must be anchored against flotation and elevated so the bottom of the frame sits at or above the Florida Building Code's required elevation, under Village Code of Ordinances Sec. 5-69 and 5-70.
Sec. 5-69. - Anchoring. All new manufactured homes and replacement manufactured homes shall be installed using methods and practices which minimize flood damage and shall be securely anchored to an adequately anchored foundation system to resist flotation, collapse or lateral movement. Methods of anchoring include, but are not limited to, use of over-the-top or frame ties to ground anchors. This anchoring requirement is in addition to applicable state and local anchoring requirements for wind resistance. ... Sec. 5-70. - Elevation. All manufactured homes that are placed, replaced, or substantially improved in flood hazard areas shall be elevated such that the bottom of the frame is at or above the elevation required in the Florida Building Code, Residential Section R3222.2 (Zone A).
Full Breakdown
Sec. 5-69 (Anchoring) requires every new or replacement manufactured home installed in a Wellington flood hazard area to be installed using methods and practices that minimize flood damage and to be securely anchored to an adequately anchored foundation system that resists flotation, collapse or lateral movement; the code names over-the-top and frame ties to ground anchors as acceptable methods, and states that this anchoring duty applies in addition to the separate state and local anchoring requirements for wind resistance that hurricane winds already impose. Sec.
5-70 (Elevation) then requires the home itself to be elevated so the bottom of its frame sits at or above the elevation set by Florida Building Code, Residential Section R322.2 for Zone A, before the placement, replacement or substantial improvement is complete. Sec. 5-68 requires the foundation under that elevated home to be permanent and reinforced, built to the same Residential Section R322.2 foundation standard, and Sec. 5-67 bars manufactured homes from floodways altogether and requires any home that is permitted in a flood hazard area to be installed by an installer licensed under F.S.
Section 320.8249. Sec. 5-71 (Enclosures) then requires any enclosed area built beneath the elevated home to meet the same Section R322.2 enclosure standard, so flood water can pass through rather than build up against the structure during a storm.
Violations & Fines
Placing, replacing or substantially improving a manufactured home in a Wellington flood hazard area without the anchoring required by Sec. 5-69, without elevating it to the Section R322.2 elevation required by Sec. 5-70, or without a licensed installer under Sec. 5-67, is a violation the floodplain administrator enforces under the notice and abatement procedure in Sec. 5-51 through 5-54, in addition to any Florida Building Code inspection failure on the same installation.
Frequently Asked Questions
How high must a manufactured home be elevated in a Wellington flood zone?
Are manufactured homes allowed in Wellington's floodways?
What anchoring does Wellington require for manufactured homes in flood zones?
Sources & Official References
Other rules in Wellington
Florida rules heatmap·Compare Wellington to another location·View the Florida hurricane preparedness overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Flood Elevation in Nearby Cities
How other cities in Palm Beach County handle flood elevation.