Norfolk, VA Hurricane Preparedness: Roof Standards (2026)
Key Facts
- Governing section
- Norfolk Code § 11.1-4
- Minimum wind design speed
- 100 MPH sustained
- Roof live load
- 20 lbs per sq ft
- Roof snow load
- 10 lbs per sq ft
- Seismic zone
- Zone 1
- Minimum footing depth
- 12 inches below grade
Summary
Norfolk sets its own wind and roof-load design standards on top of the state building code under Code of Ordinances Sec. 11.1-4. Every exposed structure must resist a minimum sustained wind speed of 100 miles per hour, and roofs are designed to a combined live and snow load requirement set by the city's local criteria table.
As provided for by the USBC, the following standards are established by the City of Norfolk to address those climatic and geographic conditions unique thereto: 11.1-4.1. Wind load. All exposed structures or parts of structures shall be designed to resist the pressures due to wind in any direction, as set forth in applicable sections of the USBC, based on a minimum sustained (1-minute measured wind) wind speed of 100 MPH. 11.1-4.2. Climatic and geographic design criteria. Design criteria for the City of Norfolk is established as follows: Roof Live Load 20 (lbs. per sq. ft.), Roof Snow Load 10 (lbs. per sq. ft.), Wind Velocity 100 MPH, Seismic Condition Zone 1. 1 Roof live load and snow load are addictive. 3 Minimum footing depth twelve (12) inches below finished grade.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 166).
Full Breakdown
Sec. 1 requires all exposed structures or parts of structures to be designed to resist wind pressure in any direction based on a minimum sustained one-minute measured wind speed of 100 miles per hour, referencing the applicable USBC wind provisions. Sec. 2's climatic and geographic design criteria table then sets a roof live load of 20 pounds per square foot and a roof snow load of 10 pounds per square foot for the city, noting the two loads are additive rather than substituted for each other.
The same table places Norfolk in Seismic Zone 1 and confirms the city is subject to weathering, frost line depth, termite, and decay design considerations. Footnote 2 requires 2,500-pound compressive strength concrete grade where frost protection applies, and footnote 3 sets a minimum footing depth of twelve inches below finished grade. Sec. 3 ties the base flood level, the 100-year flood elevation, to whatever the separate zoning ordinance establishes rather than setting its own number here. Sec. 5 requires water service piping to be installed at least eighteen inches below grade and sewers at least twelve inches below grade, both below the recorded frost penetration depth.
These figures were adopted by Ord. No. 36,932 in 1992 and apply on top of, not instead of, the wind, flood, and structural provisions already built into the Virginia Uniform Statewide Building Code that Sec. 1-1 adopts citywide.
Violations & Fines
Constructing or altering a structure that fails to meet the 100 MPH wind design or the roof live/snow load criteria in Sec. 11.1-4 violates the adopted building code under Sec. 11.1-2, which bars building, altering, or using any USBC-regulated structure in conflict with its provisions; the code official enforces compliance under Sec. 11.1-2.1 before issuing a certificate of occupancy.
Frequently Asked Questions
What wind speed must Norfolk buildings be designed for?
What roof load does Norfolk require for new construction?
Does Norfolk set its own flood elevation standard in this code?
Sources & Official References
Other rules in Norfolk
Compare Norfolk to another location·View the Virginia hurricane preparedness overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.