Eden Prairie, MN Noise from Specific Sources: HVAC & Mechanical Noise (2026)
Key Facts
- Rule
- outdoor air devices must meet Table I limits
- Exception
- window air conditioning units
- Covers
- central AC, heat pumps, similar equipment
- Governing limits
- Subdivision 4's day/night Table I
- Administered by
- City Manager or designee
- Penalty
- Chapter 9 misdemeanor, City Code § 9.99
Summary
In the City of Eden Prairie, City Code § 9.41, Subdivision 5 bars anyone from permanently installing an outdoor air circulation device, central air conditioning, heat pumps and similar equipment, unless it meets the Table I noise limits in Subdivision 4. A window air conditioner is the sole named exception. The rule applies wherever the unit sits outdoors, not just at the property line.
Air circulation device means a mechanism designed and used for the controlled flow of air used in ventilation, cooling, or conditioning, including, but not limited to, central and window air conditioning units. ... Subd. ... 5. Air Circulation Devices. No person shall permanently install or place any air circulation device, except a window air condition unit, in any outdoor location such that the device in that location does not comply with the noise level standards prescribed in Subdivision 4.
Full Breakdown
City Code § 9.41 defines an air circulation device in Subdivision 1 as any mechanism used for the controlled flow of air in ventilation, cooling or conditioning, expressly including central and window air conditioning units. Subdivision 5 then bars anyone from permanently installing or placing such a device in an outdoor location if it does not comply with the noise level standards set out in Subdivision 4's Table I, the same day and night limits that apply to any other noise source: 65 dBA L10/60 dBA L50 by day for residential land, falling to 55/50 at night, versus 70/65 for Commercial, Office and Public land and 80/75 for Industrial land at all hours.
A window air conditioning unit is the single exception the ordinance carves out. Because the rule is written around installation location rather than a separate decibel table for HVAC equipment, a heat pump, central condenser or similar outdoor unit placed close to a property line, or in a location where its running noise pushes the receiving property over the applicable Table I number, violates Subdivision 5 even if the unit itself is not unusually loud. The City Manager or a designee administers and tests for compliance under Subdivision 7, may call on the Minnesota Pollution Control Agency for measurement, and enforcement proceeds the same way as any other noise complaint: written notice to the owner or occupant ordering correction within a stated time, with a missed deadline treated as a further violation and the Chapter 9 misdemeanor penalty in City Code § 9.99 applying unless the City instead seeks an injunction or abatement order under Subdivision 9.
Violations & Fines
A noncompliant air circulation device draws the same enforcement as any other noise source under Section 9.41: written notice from the City Manager's office to the owner or occupant, ordering the unit relocated or otherwise brought into compliance within the deadline stated in the notice. A missed deadline is treated as a further violation, punishable under the Chapter 9 misdemeanor penalty in City Code § 9.99, or by injunction or abatement action.
Frequently Asked Questions
Can I install a central air conditioner outside my Eden Prairie home?
What if my neighbor's HVAC unit is too loud?
Are there separate decibel numbers just for air conditioners?
Sources & Official References
Other rules in Eden Prairie
Compare Eden Prairie to another location·View the Minnesota noise from specific sources overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.