Skip to main content
CityRuleLookup

Eden Prairie, MN Noise from Specific Sources: HVAC & Mechanical Noise (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Rule
outdoor air devices must meet Table I limits
Exception
window air conditioning units
Covers
central AC, heat pumps, similar equipment
Governing limits
Subdivision 4's day/night Table I
Administered by
City Manager or designee
Penalty
Chapter 9 misdemeanor, City Code § 9.99

Summary

In the City of Eden Prairie, City Code § 9.41, Subdivision 5 bars anyone from permanently installing an outdoor air circulation device, central air conditioning, heat pumps and similar equipment, unless it meets the Table I noise limits in Subdivision 4. A window air conditioner is the sole named exception. The rule applies wherever the unit sits outdoors, not just at the property line.

Air circulation device means a mechanism designed and used for the controlled flow of air used in ventilation, cooling, or conditioning, including, but not limited to, central and window air conditioning units. ... Subd. ... 5. Air Circulation Devices. No person shall permanently install or place any air circulation device, except a window air condition unit, in any outdoor location such that the device in that location does not comply with the noise level standards prescribed in Subdivision 4.

Full Breakdown

City Code § 9.41 defines an air circulation device in Subdivision 1 as any mechanism used for the controlled flow of air in ventilation, cooling or conditioning, expressly including central and window air conditioning units. Subdivision 5 then bars anyone from permanently installing or placing such a device in an outdoor location if it does not comply with the noise level standards set out in Subdivision 4's Table I, the same day and night limits that apply to any other noise source: 65 dBA L10/60 dBA L50 by day for residential land, falling to 55/50 at night, versus 70/65 for Commercial, Office and Public land and 80/75 for Industrial land at all hours.

A window air conditioning unit is the single exception the ordinance carves out. Because the rule is written around installation location rather than a separate decibel table for HVAC equipment, a heat pump, central condenser or similar outdoor unit placed close to a property line, or in a location where its running noise pushes the receiving property over the applicable Table I number, violates Subdivision 5 even if the unit itself is not unusually loud. The City Manager or a designee administers and tests for compliance under Subdivision 7, may call on the Minnesota Pollution Control Agency for measurement, and enforcement proceeds the same way as any other noise complaint: written notice to the owner or occupant ordering correction within a stated time, with a missed deadline treated as a further violation and the Chapter 9 misdemeanor penalty in City Code § 9.99 applying unless the City instead seeks an injunction or abatement order under Subdivision 9.

Violations & Fines

A noncompliant air circulation device draws the same enforcement as any other noise source under Section 9.41: written notice from the City Manager's office to the owner or occupant, ordering the unit relocated or otherwise brought into compliance within the deadline stated in the notice. A missed deadline is treated as a further violation, punishable under the Chapter 9 misdemeanor penalty in City Code § 9.99, or by injunction or abatement action.

Frequently Asked Questions

Can I install a central air conditioner outside my Eden Prairie home?
Yes, but City Code § 9.41, Subdivision 5 requires the unit's noise to stay within the Table I limits for your zoning district once installed outdoors, currently 65 dBA L10 by day and 55 dBA L10 at night for residential land. A window air conditioning unit is exempt from this placement rule.
What if my neighbor's HVAC unit is too loud?
Report it to the City Manager's office under Section 9.41. If the unit's noise at your property line exceeds the applicable Table I limit, the City can order the owner to correct the installation within a stated deadline, and a missed deadline is a further violation under Section 9.99.
Are there separate decibel numbers just for air conditioners?
No. Subdivision 5 ties air circulation devices to the same Table I limits that govern every other noise source under Subdivision 4, rather than setting a distinct HVAC table, so the applicable number depends on whether the receiving land is Residential, Commercial or Industrial.

Sources & Official References

Other rules in Eden Prairie

All Eden Prairie rules

Compare Eden Prairie to another location·View the Minnesota noise from specific sources overview

Get notified when HVAC & Mechanical Noise in Eden Prairie, MN changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.