Framingham, MA Noise from Specific Sources: HVAC & Mechanical Noise (2026)
Key Facts
- Named source
- "Building HVAC systems," § 332-5
- Mixed-use limit
- 60 dB(A) day/evening, 55 dB(A) night
- Residential limit
- 55/50/45 dB(A) day/evening/night
- Grandfather date
- HVAC units before Oct. 29, 2019
- Enforcing agency
- Framingham Police Department
- Second offense fine
- $100 within 12 months
Summary
Framingham names building HVAC systems as a regulated stationary noise source under Section 332-5. HVAC noise measured at a mixed residential-commercial property line, such as a hotel or hospital, cannot exceed 60 dB(A) by day, 60 dB(A) in the evening or 55 dB(A) at night, enforced by the Framingham Police Department.
Stationary sources of noise may include, but are not limited to, building HVAC systems, power generation facilities, industrial equipment, water or sewage pump stations, railroad and subway layover facilities, electric power transformers, commercial factories and plants, truck depots, and recreational events. The noise level emitted by stationary noise sources shall not exceed the limits contained in Table 1 when measured at the property line of the receiving property. ... Residential within commercial: mixed land use, primarily commercial areas but with some residential development, hotel/motels, hospitals, etc. 60 dB(A) Leq (1min) or background Leq (1min), whichever is greater 60 dB(A) Leq (1min) or background Leq (1min), whichever is greater 55 dB(A) Leq (1min) or background Leq (1min), whichever is greater
Full Breakdown
Section 332-5 of the Framingham City Code lists "building HVAC systems" first among the examples of stationary noise sources, alongside power generation facilities, industrial equipment, water or sewage pump stations, electric power transformers and commercial factories. Any stationary source, including rooftop or ground-mounted HVAC condensers and heat pumps, cannot exceed the dB(A) limits in Table 1 when measured at the property line of the receiving property. For a mixed residential-commercial receiver, such as a hotel, motel or hospital sited near commercial HVAC equipment, Table 1 caps the noise at 60 dB(A) Leq (1 minute) during both the daytime (7:00 a.m. to 6:00 p.m.) and evening (6:00 p.m. to 10:00 p.m.) bands, dropping to 55 dB(A) at night (10:00 p.m. to 7:00 a.m.), or the measured background level if that reading is louder.
Section 332-9 requires compliance readings to come from a calibrated Type 2 sound level meter under ASTM standards, with make, model, calibration date and weather conditions logged. Section 332-10A grandfathers HVAC units already operating lawfully before the chapter's October 29, 2019 effective date, but any HVAC unit installed or upgraded afterward must meet the Table 1 limits regardless of when the building itself was built.
Violations & Fines
A first HVAC noise complaint that is substantiated draws a written warning with a deadline to reduce the noise to Table 1 levels. A second violation of the same equipment within twelve months costs $100, and any further violation in that period costs $300 under Section 332-12. If the HVAC unit sits on a rental property not owned by the offender, the City notifies the property owner in writing.
Frequently Asked Questions
Does Framingham regulate HVAC unit noise?
What decibel limit applies to an HVAC unit near my home?
Is an old HVAC unit exempt from the noise limit?
Sources & Official References
Other rules in Framingham
Compare Framingham to another location·View the Massachusetts noise from specific sources overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.