Arvada, CO Noise Ordinances: Decibel Limits (2026)
Key Facts
- Residential/mixed-use limit
- 55 dB(A) day, 50 dB(A) night
- Commercial limit
- 60 dB(A) day, 55 dB(A) night
- Light industrial limit
- 70 dB(A) day, 65 dB(A) night
- Heavy industrial limit
- 75 dB(A) day and night
- Minimum measurement window
- 10 minutes
- Compliance threshold
- Exceed limit under 10% of period
- Code section
- Arvada City Code § 38-91
Summary
Arvada caps stationary noise sources at fixed decibel levels tied to zoning district and time of day under Table I of Section 38-91, from 50 dB(A) at night in residential zones up to 75 dB(A) around the clock in heavy industrial areas.
It shall be unlawful for any person to operate or cause or permit to be operated any stationary source of noise which creates a sound pressure level that exceeds the limits set forth in Table I for more than 90 percent of any measurement period. This measurement shall not be less than ten minutes when measured at the property boundary or at any point within the property affected by the noise.
TABLE I. SOUND PRESSURE LEVEL LIMIT dB(A) Use District / Day 7:00 a.m.-9:00 p.m. / Night 9:00 p.m.-7:00 a.m.
Residential and mixed-use 55 / 50 Commercial 60 / 55 Light industrial 70 / 65 Heavy industrial 75 / 75
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: City Council Policy Manual: Supplement 1 | Code of Ordinances: Supplement 67).
Full Breakdown
Section 38-91 opens Division 3 of the noise chapter, 'Community Noise Levels,' and sets the numeric backbone behind the conduct-based rules in Division 2. It bars operating any stationary noise source above the Table I sound-pressure limit for more than 90 percent of any measurement period, with the measurement window never shorter than ten minutes, taken at the property boundary or anywhere on the affected property. ): residential and mixed-use districts at 55 dB(A) by day and 50 dB(A) by night, commercial districts at 60/55 dB(A), light industrial at 70/65 dB(A), and heavy industrial at 75 dB(A) around the clock.
A planned unit development is measured against the table entry matching its predominant land use as set in the PUD plan. The following sections adjust how a reading is taken: Section 38-94 allows a correction for the duration of an intermittent noise, and Section 38-95 allows a correction for tonal or impulsive character, either of which can push a borderline reading over the limit even if the raw average would pass. Section 38-96 exempts organized school-band practices and performances. Because Division 3 sets its own numeric standard rather than relying on the conduct language in Section 38-62, code enforcement or police can cite a stationary source, such as a rooftop HVAC unit, generator, or outdoor speaker, purely on a measured reading that exceeds the applicable district limit for more than 90 percent of the sampling period.
Violations & Fines
A stationary source that exceeds its district's Table I limit for more than 90 percent of a ten-minute or longer measurement period violates Section 38-91. Because Article II sets no separate fine schedule, Section 38-33 routes the penalty to the citywide general penalty in Section 1-5: up to $2,650.00 in fines, up to 364 days in jail, or both, with each day of a continuing exceedance charged as a separate offense.
Frequently Asked Questions
Where is sound measured to check compliance?
What decibel limit applies to a house in a residential neighborhood at night?
Can a reading be adjusted for how the noise sounds, not just its volume?
Sources & Official References
Other rules in Arvada
Compare Arvada to another location·View the Colorado noise ordinances overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.