Parker, CO Outdoor Lighting: Dark Sky Rules (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Maximum lumens
25,000 lumens per fixture
Shielding
Full cutoff, aimed 90° downward
Color temperature
Below 5001 Kelvin
Curfew reduction
70% dimmed 1 hour after closing
Exempt fixtures
900 lumens or less
Cutoff exception
Planning Director may approve

Summary

Section 13.08.110(e) of the Parker Municipal Code requires every outdoor light fixture in the Town, except small residential lamps and a short list of exemptions, to be full cutoff and aimed straight down so no more than ten percent of its output escapes above eighty degrees from vertical. Fixtures are capped at 25,000 lumens, must run below 5001 Kelvin, and most nonresidential lighting has to dim seventy percent an hour after closing.

(1)Maximum lumens. No single lamp or luminaire shall exceed twenty-five thousand (25,000) lumens.(2)Lighting types and efficiency.a.Light sources shall be color-correct types and shall have a correlated color temperature (CCT) below 5001 degrees Kelvin.b.LED or other high efficiency light fixtures shall be used to the maximum extent practicable.(3)Shielding required.a.All light fixtures shall be shielded and directed to avoid glare and overspill onto adjacent property.b.All light fixtures shall be shielded using full cutoff light fixtures that are directed downwards (ninety (90) degrees from true vertical) and no more than ten (10) percent of total lumens measurable at or above eighty (80) degrees above the vertical axis of the light fixture unless an exception is approved by the Planning Director. ... (8)Lighting curfew.a.Except as modified by paragraph b. below, all illumination shall be reduced by at least seventy (70) percent one (1) hour after the close of business, and shall not exceed that level of illumination until at least one (1) hour prior to the opening of the business.

Full Breakdown

Section 13.08.110 states its purpose plainly: providing adequate safety lighting while minimizing light pollution, light trespass, and glare townwide. The rule applies in every zoning district, with exemptions in Subsection (c) for luminaires of 900 lumens or less, Town-installed street and traffic lighting, temporary holiday and construction lighting, flag and public-art lighting, and airport navigational lighting; single-family, single-family attached, and duplex properties are exempt from the shielding and trespass standards in Subsections (d) through (f) but still cannot exceed 900 lumens per fixture. For everything else, Subsection (e) sets the core dark-sky standards: no single lamp or luminaire may exceed 25,000 lumens, light sources must be color-correct with a correlated color temperature below 5001 Kelvin, and every fixture must be shielded with a full cutoff design directed ninety degrees downward from true vertical, with no more than ten percent of total lumens measurable at or above eighty degrees above vertical.

The Planning Director can grant an exception to the cutoff angle, but not to the lumen cap. Subsection (e)(8) adds a lighting curfew: illumination must be reduced at least seventy percent one hour after a business closes and stay reduced until an hour before it reopens, a rule that exempts residential uses and parks, which instead dim fifty percent after activity ends. Nonconforming fixtures installed before these standards took effect are governed separately under Section 13.01.070(f)(1), and all fixtures must be kept in working, undamaged condition under Section 13.08.130(a)(8).

Violations & Fines

A fixture that exceeds the 25,000-lumen cap, lacks full cutoff shielding, or skips the seventy-percent curfew reduction is out of compliance with Section 13.08.110(e) and can be flagged by Community Development during Site Plan review or a complaint-driven inspection, which can require retrofitting or replacement of the fixture. Persistent noncompliance is enforceable as a Municipal Code violation through Parker Municipal Court.

Frequently Asked Questions

Does the Town of Parker require outdoor lights to be shielded?
Yes. Section 13.08.110(e)(3) requires nearly every outdoor light fixture in Parker to use a full cutoff design directed ninety degrees downward, with no more than ten percent of total lumens escaping above eighty degrees from vertical, so light stays on the property instead of spilling into the sky or onto neighbors.
What is the brightest outdoor light fixture allowed in Parker?
No single lamp or luminaire may exceed 25,000 lumens under Section 13.08.110(e)(1). Fixtures producing 900 lumens or less are exempt from the dark-sky standards entirely, which is why small residential porch and landscape lights generally do not need shielding review.
Do Parker businesses have to turn down outdoor lighting at night?
Most nonresidential lighting does. Section 13.08.110(e)(8) requires illumination to be cut by at least seventy percent one hour after a business closes, staying reduced until an hour before it reopens. Residential uses and lighting for outdoor recreation facilities follow a separate reduction schedule instead.
Are single-family homes exempt from Parker's dark-sky lighting rules?
Largely, yes. Section 13.08.110(c)(9) exempts single-family detached, single-family attached, and duplex properties from the shielding, trespass, and curfew standards in Subsections (d) through (f), though those properties still cannot install a fixture exceeding 900 lumens.

Sources & Official References

Other rules in Parker

All Parker rules

Compare Parker to another location·View the Colorado outdoor lighting overview

Get notified when Dark Sky Rules in Parker, CO changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.