Monroe Township (Gloucester County), NJ Outdoor Lighting: Light Trespass & Shielding (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

Property line limit
0.25 footcandles maximum at any property or right-of-way line
Shielding
Light shields on all lights to control glare
Visibility
Light source never visible from adjacent properties
Exception
Points of ingress and egress for vehicles
Pole mounting height
A maximum of 16 feet and a minimum of 12 feet
Street luminaire height
Should not exceed 25 feet

Summary

In Monroe Township, Gloucester County, New Jersey, § 175-116 requires light shields on all lights, bars the light source from being visible from adjacent properties, and permits a maximum of 0.25 footcandles at any property line or right-of-way line. Vehicle ingress and egress points are the one exception.

A. Illumination levels. (1) General parking and walkways illumination. (a) Average maintained horizontal illumination at ground level shall be as follows: ... (b) Luminaires. Light shields are to be used on all lights to control glare. At no time shall the light source be visible from adjacent properties. Shields are to be used to prevent spillover onto adjacent properties and/or other areas where light intrusion is unwanted. A maximum of 0.25 footcandles is permitted at any property line and/or right-of-way line. (However, this does not apply to points of ingress and egress for vehicles.) ... (e) The maximum footcandle level should not exceed 0.25 footcandles over the right-of-way line.

Full Breakdown

Section 175-116 is the Township's lighting standard, amended 3-3-1997 by Ord. No. O-7-97. Its luminaire rule in Subsection A(1)(b) has four parts: light shields on all lights to control glare, no visible light source from adjacent properties at any time, shields to prevent spillover onto adjacent properties and other areas where light intrusion is unwanted, and a maximum of 0.25 footcandles at any property line and/or right-of-way line. The 0.25 limit does not apply to points of ingress and egress for vehicles.

The rest of the section sets design targets around that limit. Pole-mounted luminaires should be a maximum of 16 feet and a minimum of 12 feet above the ground. Lights should be designed so they can be reduced or turned off outside the primary hours of the use. Spotlights, if used, are placed on buildings so as not to cause glare and positioned at a maximum of 45º to the building wall. Lighting of buildings is discouraged other than for identification signs, locating entrances and exits, or security.

The parking and walkway table sets a maximum average of 0.8 footcandles on pavement for residential-type parking lots such as church and park lots, 2.4 for office or strip mall lots and 4.0 for shopping centers or malls. For streets, Subsection A(2)(e) says the maximum footcandle level should not exceed 0.25 footcandles over the right-of-way line, and Subsection A(2)(h) says the height of a luminaire should not exceed 25 feet.

Subsection B(1) requires a designated lighting plan, prepared with a landscape plan. It must show all existing lights within 100 feet of the site, the luminaire detail with lamp type, manufacturer and wattage, pole and mounting heights, and photometric data with isolux lines at 2.0, 1.0, 0.50 and 0.25 footcandles.

Violations & Fines

Section 175-116 prints no fine of its own. It operates through the lighting plan required in Subsection B(1), which has to show photometric lines down to 0.25 footcandles, the luminaire details and every existing light within 100 feet of the site. The plan is where the 0.25 footcandle property-line limit gets drawn out.

Frequently Asked Questions

How much light can spill onto a neighbor's property in Monroe Township?
Section 175-116(A)(1)(b) permits a maximum of 0.25 footcandles at any property line and/or right-of-way line. Shields are to be used to prevent spillover onto adjacent properties, and at no time shall the light source be visible from adjacent properties.
Does the 0.25 footcandle limit apply at driveways?
No. The code states that the 0.25 footcandle maximum does not apply to points of ingress and egress for vehicles. Everywhere else along a property line or right-of-way line the limit holds, and the shielding and no-visible-source requirements still apply to the lights.
How tall can parking lot light poles be?
Subsection A(1)(c) says the maximum mounting height of a pole-mounted luminaire should be a maximum of 16 feet and a minimum of 12 feet, measured from the ground. Exposed concrete bases of light poles should be finished to be similar in color to the building facade.
What does a developer have to submit about lighting?
Subsection B(1) requires a designated lighting plan prepared with a landscape plan. It shows all existing lights within 100 feet of the site, luminaire details, pole heights, and photometric data with isolux lines up to 2.0, 1.0, 0.50 and 0.25 footcandles, noted as initial or maintained.

Sources & Official References

Other rules in Monroe Township (Gloucester County)

All Monroe Township (Gloucester County) rules

Compare Monroe Township (Gloucester County) to another location·View the New Jersey outdoor lighting overview

Get notified when Light Trespass & Shielding in Monroe Township (Gloucester County), NJ changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.