Ankeny, IA Rental Property Rules: Repairs & Habitability (2026)
Key Facts
- Living room minimum
- 120 square feet
- Bedroom minimum
- 70 sq ft, +50 per extra occupant
- Heat supply required
- September 15 to May 15
- Receptacle rule
- 2 outlets/room, GFCI near water
- Adopted base code
- 2024 Intl. Property Maintenance Code
- First-offense penalty
- up to $750 civil penalty
Summary
Ankeny's Property Maintenance and Housing Code sets rental-specific physical minimums on top of the 2024 International Property Maintenance Code: 120 square feet for a living room, 70 for a bedroom, seasonal heat from September 15 through May 15, and GFCI-protected receptacles near water and in every habitable room. The Building Safety Department enforces the standard.
Section 404.4.1 Room area. ... Every living room shall contain at least 120 square feet and every bedroom shall contain at least 70 square feet. Where more than two persons occupy a bedroom the required floor area shall be increased at the rate of 50 square feet for each occupant in excess of two. ... Section 602.3 Heat supply. ... (from date) September 15 (to date) May 15 ... Section 605.2 Receptacles. ... Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounding-type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain at least one receptacle and shall have ground fault circuit interrupter protection. All 125-volt, single phase, 15- and 20- ampere receptacles, in rental dwelling units, within six feet of the edge of a sink, bathtub or shower stall shall be provided with ground fault circuit interrupter protection.
Full Breakdown
The City of Ankeny adopts the 2024 International Property Maintenance Code as the Ankeny Property Maintenance and Housing Code under Code of Ordinances Section 177.02, then locally amends specific IPMC sections to fix the physical habitability floor for every rental dwelling in the city. Room area is set at 120 square feet for a living room and 70 square feet for a bedroom under Section 177.15, amending IPMC Section 404.4.1, and the bedroom minimum rises by 50 square feet for each occupant beyond two. Heat supply and occupiable work-space temperature requirements apply from September 15 through May 15 each year under Sections 177.16 and 177.17, amending IPMC Sections 602.3 and 602.4, so a landlord who lets a furnace sit idle inside that window is out of compliance.
Electrical coverage is set out in Section 177.18: two remote receptacle outlets per habitable room, a grounded or GFCI laundry outlet, GFCI protection in every bathroom, and GFCI protection on any 125-volt 15- or 20-amp outlet within six feet of a sink, tub or shower in a rental unit. Section 102.12.2 extends the housing code to all rental dwellings, including short-term rentals of 30 days or less under Iowa Code Chapter 423A, while exempting owner-occupied duplexes, single-family homes occupied by immediate family, state-inspected transient shelters and government-owned housing.
The Ankeny Department of Building Safety and the Community Development Department administer these standards, and Section 102.12.15 makes a violation of the chapter a municipal infraction under Chapter 4.
Violations & Fines
A rental dwelling that fails these standards is a municipal infraction under Section 102.12.15, punishable under Code of Ordinances Section 4.03 by a civil penalty of up to $750 for a first offense and up to $1,000 for each repeat offense, with every day the violation continues counted as a new repeat offense. The Code Official may also seek an injunction under Sections 102.12.16 through 102.12.18 to bar occupancy until the property is brought into compliance.
Frequently Asked Questions
Is Ankeny required to provide heat in rental units?
What is the minimum bedroom size for an Ankeny rental?
What electrical outlets must an Ankeny rental have?
Sources & Official References
Other rules in Ankeny
Compare Ankeny to another location·View the Iowa rental property rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.