Waco, TX Rental Property Rules: Repairs & Habitability (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Winter heat minimum
68°F in all habitable rooms, bathrooms, toilet rooms
Work-space heat minimum
65°F during occupied hours
Summer cooling standard
At least 15°F below outdoor temp, capped 85°F
Cooling floor
Owner never required to cool below 70°F
Heat-wave defense
85°F room allowed if outside tops 110°F
Code source
IPMC §§ 602.3, 602.4, 603.7 as locally amended

Summary

Waco's local amendments to the International Property Maintenance Code force landlords to keep every rented dwelling unit at a minimum 68°F in winter and no more than 15 degrees warmer than outside air, capped at 85°F, in summer. Sec. 6-27(23) and (25) apply the standard to any owner or operator who rents, leases, or lets a dwelling, rooming unit, dormitory, or guestroom.

(23)IPMC Section 602.3 Heat Supply, shall read: Every owner and operator of any building who rents, leases or lets one or more dwelling unit, rooming unit, dormitory or guestroom on terms, either expressed or implied, to furnish heat to the occupants thereof shall supply heat to maintain a temperature of not less than 68F in all habitable rooms, bathrooms, and toilet rooms. ... (25)IPMC Section 603.7 Cooling Facilities Required, shall be added to read:(a)An owner shall:1.Provide and maintain, in operating condition, refrigerated air equipment capable of maintaining a room temperature of at least 15 degrees cooler than the outside temperature, but in no event higher than 85°F in each habitable room. ... (c)It is a defense to prosecution under this paragraph that at least one habitable room is 85°F, if the outside temperature is over 110°F.(d)At no time is an owner required to provide cooling facilities capable of maintaining a room temperature below 70°F.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 88).

Full Breakdown

Chapter 6, Sec. 6-27 amends the 2024 International Property Maintenance Code as adopted in Waco. " A companion clause, subsection (24), sets a 65°F floor for occupiable work spaces during occupied hours, with exceptions for spaces that need special processing temperatures or where occupants are doing vigorous physical work. 7, Cooling Facilities Required, obligating an owner to provide and maintain, in operating condition, refrigerated air equipment capable of holding a room at least 15 degrees cooler than the outside temperature but never above 85°F in any habitable room, measured three feet above the floor near the room's center and two feet in from each exterior wall.

It is a defense to a cooling-code prosecution if at least one habitable room reaches 85°F when the outside temperature tops 110°F, and an owner is never required to cool a room below 70°F. Sec. 6-27(1) separately requires a permit before construction, alteration, or repair work, while Sec. 6-27(9) lets the code official order demolition of a structure so dilapidated that repair is unreasonable, and Sec. 6-27(3) lets the code official declare a unit unfit for human occupancy for lacking heat or cooling facilities altogether.

Violations & Fines

A structure that lacks required heat or cooling under the IPMC amendments can be found "unfit for human occupancy" under Sec. 6-27(3), triggering a correction order under Sec. 6-27(4) or closure under Sec. 6-27(5). Separately, Sec. 6-27(2) makes noncompliance with the Property Maintenance Code a misdemeanor or civil infraction and a strict-liability offense, with the city authorized to sue to restrain, correct, or abate the violation and place a lien on the property.

Frequently Asked Questions

Is my landlord required to provide heat in Waco?
Yes. Sec. 6-27(23) rewrites the Property Maintenance Code's heat-supply section so that any owner or operator who rents, leases, or lets a dwelling unit, rooming unit, dormitory, or guestroom must supply enough heat to keep every habitable room, bathroom, and toilet room at a minimum of 68°F.
Does Waco require landlords to provide air conditioning?
Yes. Sec. 6-27(25) adds a cooling-facilities requirement obligating owners to maintain refrigerated air equipment that keeps each habitable room at least 15 degrees cooler than the outside temperature, though never above 85°F, measured three feet above the floor near the room's center.
What can I do if my rental unit has no heat or air conditioning?
A unit that lacks required heat or cooling can be declared unfit for human occupancy under Sec. 6-27(3), which lets the code official order corrections under Sec. 6-27(4) or, if the unit is vacant and unsafe, close it under Sec. 6-27(5) and bill the owner for the closure.

Sources & Official References

Other rules in Waco

All Waco rules

Texas rules heatmap·Compare Waco to another location·View the Texas rental property rules overview

Get notified when Repairs & Habitability in Waco, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.