Waco, TX Rental Property Rules: Repairs & Habitability (2026)
Key Facts
- Winter heat minimum
- 68°F in all habitable rooms, bathrooms, toilet rooms
- Work-space heat minimum
- 65°F during occupied hours
- Summer cooling standard
- At least 15°F below outdoor temp, capped 85°F
- Cooling floor
- Owner never required to cool below 70°F
- Heat-wave defense
- 85°F room allowed if outside tops 110°F
- Code source
- IPMC §§ 602.3, 602.4, 603.7 as locally amended
Summary
Waco's local amendments to the International Property Maintenance Code force landlords to keep every rented dwelling unit at a minimum 68°F in winter and no more than 15 degrees warmer than outside air, capped at 85°F, in summer. Sec. 6-27(23) and (25) apply the standard to any owner or operator who rents, leases, or lets a dwelling, rooming unit, dormitory, or guestroom.
(23)IPMC Section 602.3 Heat Supply, shall read: Every owner and operator of any building who rents, leases or lets one or more dwelling unit, rooming unit, dormitory or guestroom on terms, either expressed or implied, to furnish heat to the occupants thereof shall supply heat to maintain a temperature of not less than 68F in all habitable rooms, bathrooms, and toilet rooms. ... (25)IPMC Section 603.7 Cooling Facilities Required, shall be added to read:(a)An owner shall:1.Provide and maintain, in operating condition, refrigerated air equipment capable of maintaining a room temperature of at least 15 degrees cooler than the outside temperature, but in no event higher than 85°F in each habitable room. ... (c)It is a defense to prosecution under this paragraph that at least one habitable room is 85°F, if the outside temperature is over 110°F.(d)At no time is an owner required to provide cooling facilities capable of maintaining a room temperature below 70°F.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 88).
Full Breakdown
Chapter 6, Sec. 6-27 amends the 2024 International Property Maintenance Code as adopted in Waco. " A companion clause, subsection (24), sets a 65°F floor for occupiable work spaces during occupied hours, with exceptions for spaces that need special processing temperatures or where occupants are doing vigorous physical work. 7, Cooling Facilities Required, obligating an owner to provide and maintain, in operating condition, refrigerated air equipment capable of holding a room at least 15 degrees cooler than the outside temperature but never above 85°F in any habitable room, measured three feet above the floor near the room's center and two feet in from each exterior wall.
It is a defense to a cooling-code prosecution if at least one habitable room reaches 85°F when the outside temperature tops 110°F, and an owner is never required to cool a room below 70°F. Sec. 6-27(1) separately requires a permit before construction, alteration, or repair work, while Sec. 6-27(9) lets the code official order demolition of a structure so dilapidated that repair is unreasonable, and Sec. 6-27(3) lets the code official declare a unit unfit for human occupancy for lacking heat or cooling facilities altogether.
Violations & Fines
A structure that lacks required heat or cooling under the IPMC amendments can be found "unfit for human occupancy" under Sec. 6-27(3), triggering a correction order under Sec. 6-27(4) or closure under Sec. 6-27(5). Separately, Sec. 6-27(2) makes noncompliance with the Property Maintenance Code a misdemeanor or civil infraction and a strict-liability offense, with the city authorized to sue to restrain, correct, or abate the violation and place a lien on the property.
Frequently Asked Questions
Is my landlord required to provide heat in Waco?
Does Waco require landlords to provide air conditioning?
What can I do if my rental unit has no heat or air conditioning?
Sources & Official References
Other rules in Waco
Texas rules heatmap·Compare Waco to another location·View the Texas rental property rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.