Kirkwood, MO Solar Energy: Panel Permits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Use classification
Accessory use only, never principal
Freestanding array max height
16 ft or building height, lesser
Flat-roof panel height
5 ft above roofline
Front yard placement
Prohibited for freestanding systems
Non-working panels
Must be dismantled and removed

Summary

Kirkwood allows solar energy systems only as accessory uses under § 25-51, with roof panels capped at the structure's height limit and freestanding arrays limited to 16 feet or the principal building's height, whichever is less, and barred from front yards.

In no district shall solar energy systems and small wind-energy systems be permitted as a principal use on a lot. ... All freestanding solar energy systems shall meet the side and rear yard setbacks that are required for the principal building in the applicable zoning district. ... In no case shall freestanding solar energy systems be located within a required front yard or in front of the principal building on the lot. ... Freestanding solar energy systems shall not exceed the height of the principal building on the same lot or shall not exceed 16 feet in height, whichever is less.

Full Breakdown

Section 25-51 of the Kirkwood Code of Ordinances governs solar energy systems citywide. Under § 25-51(a), solar arrays are permitted only as accessory uses reducing on-site or utility energy consumption; they may never serve as the principal use of a lot in any zoning district. The section applies to every system installed after the Code's effective date and to any upgrade that materially changes an existing system's size or placement, per § 25-51(b). Roof-mounted panels under § 25-51(c)(1) cannot exceed the maximum allowable building height for the structure they sit on, must mount within two feet of the roofline without projecting past the peak or edge on sloped roofs, and on flat roofs are capped at five feet above the roofline unless screened by a parapet or set back at least 10 feet from the roof edge.

Freestanding ground arrays under § 25-51(c)(2) must meet the applicable district's side and rear yard setbacks, may never sit in a required front yard or ahead of the principal building, and cannot exceed the height of the principal building or 16 feet, whichever is less; all wiring must be buried. Awning-mounted systems must meet the setback for architectural features, and wall-mounted systems must sit within two inches of the exterior wall. Systems must be designed to prevent reflective glare onto adjacent properties and rights-of-way under § 25-51(c)(6), and the Director of Public Services may approve emerging technologies not otherwise addressed under § 25-51(c)(5).

Violations & Fines

Nonfunctioning or damaged solar equipment that is not dismantled and removed is a violation under § 25-51(c)(7), enforced under Article XIII. The Director of Public Services enforces the chapter per § 25-99, with appeal to the Board of Adjustment under § 25-25. Section 25-100(b) sets fines of $10 to $250 per day for a first offense, up to 10 days' imprisonment, or both, rising to $100 to $500 per day for a repeat violation at the same site.

Frequently Asked Questions

Can I install a freestanding solar array in my Kirkwood front yard?
No. Section 25-51(c)(2)(ii) prohibits freestanding solar energy systems in any required front yard or in front of the principal building on the lot, regardless of zoning district.
How tall can a ground-mounted solar array be in Kirkwood?
Section 25-51(c)(2)(iii) caps freestanding solar energy systems at the height of the principal building on the same lot, or 16 feet, whichever is less, and it must also meet the side and rear yard setbacks required for that district.
What happens to a broken solar panel that is not removed?
Section 25-51(c)(7) makes an unremoved nonfunctioning or damaged solar panel a Code violation, enforceable under Article XIII with fines starting at $10 to $250 per day under § 25-100(b).

Sources & Official References

Other rules in Kirkwood

All Kirkwood rules

Compare Kirkwood to another location·View the Missouri solar energy overview

Get notified when Panel Permits in Kirkwood, MO changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.