Provo, UT Zoning Overlays & Bonuses: Downtown Design Guide (2026)
Key Facts
- Zones covered
- DT1, DT2, GW, WG, ITOD
- Commercial ground glass, primary street
- 40% minimum
- Commercial ground glass, secondary street
- 30% minimum
- Residential ground glass, any street
- 20% minimum
- Entrance spacing, primary street
- 1 per 50 feet
- Minimum roof pitch (street-facing)
- 5:12
- Stucco/EIFS facade cap
- 20% per facade
Summary
New buildings in Provo's DT1, DT2, GW, WG, and ITOD downtown zones must meet City Code Section 14.34.295 design standards: minimum storefront glass, pedestrian entrance spacing, prohibited siding materials, and roof pitch rules. The Planning Commission can require stricter conditions or approve an equivalent alternative arrangement.
(2) Applicability... the design standards set forth in this Section shall apply to all buildings and uses located in the General Downtown (DT1), Downtown Core (DT2), Downtown Gateway (GW), West Gateway (WG), and Interim Transit Oriented Development (ITOD) zones. (a) In approving a project plan, the approving authority may impose reasonable conditions... This Section shall be interpreted to supersede other requirements of the Provo City Code which may impose more restrictive requirements. (4)(a)(i) Commercial Ground Floors. Each first floor commercial frontage situated along a primary street shall provide a minimum of forty percent (40%) completely transparent glass and on secondary streets thirty percent (30%) completely transparent glass. (6)(b) Prohibited Exterior Materials. The exterior finish material on all buildings shall not consist of vinyl or metal siding (including sheet or corrugated metal), plywood, particle board or other wood products not intended as an architectural finish product, or manufactured stone.
Official source re-checked September 8, 2026: no newer edition of the code had been published (publisher’s edition: current through Ordinance 2026-17, passed June 9, 2026).
Full Breakdown
285) requirements to every building in the General Downtown (DT1), Downtown Core (DT2), Downtown Gateway (GW), West Gateway (WG), and Interim Transit Oriented Development (ITOD) zones, and the ordinance states it supersedes any conflicting, less restrictive requirement elsewhere in the Provo City Code. Ground floors are the most enforced piece: commercial frontage on a primary street needs at least 40% transparent glass, 30% on a secondary street, while ground-floor residential frontage needs 20% transparent glass on any street. Every 50 feet of primary-street building frontage (100 feet on secondary streets, or GW/WG's 100-foot standard) must include a pedestrian entrance, and GW/WG parcels fronting Center Street must have an entrance facing Center Street.
Multi-family and mixed-use facades must be horizontally and vertically articulated with a visible break between ground and upper floors, avoid extensive blank walls, and give the building a distinct base, middle and top treatment. Exterior finish cannot be vinyl or metal siding (including sheet or corrugated metal), plywood, particle board, unfinished wood products, or manufactured stone, and stucco/EIFS/synthetic stucco finishes are capped at 20% of each facade face. Pitched roofs facing a public street must slope no less than 5:12 (2:12 for porches and attached sheds), though flat roofs remain allowed.
At least half of all residential units need a balcony of 50 square feet or more, and balconies projecting into the right-of-way are capped at 5 feet with 10 feet of sidewalk clearance. Buildings within 100 feet of a railroad right-of-way must include sound and vibration attenuating design, backed by documentation from an acoustical engineer or the materials manufacturer. Mechanical equipment needs an opaque, architecturally compatible screen sized only as large as necessary. The Planning Commission may waive individual requirements only by approving an alternative design arrangement that is equivalent to or more restrictive than the code standard.
Violations & Fines
Design Review approval under Section 14.34.280 is required before a downtown building permit is issued, and the approving authority can attach reasonable conditions consistent with these standards. Because the Planning Commission's project plan approval is the enforcement checkpoint, noncompliant plans are rejected or held pending redesign rather than fined after construction; occupancy and further permits are withheld from a project built without the required glass percentages, entrance spacing, prohibited materials, or roof pitch documented in the approved plans.
Frequently Asked Questions
Does the downtown design guide apply to my remodel?
Can Provo waive the glass or entrance requirements?
What siding is banned downtown?
How many balconies does a downtown apartment building need?
Sources & Official References
Other rules in Provo
Compare Provo to another location·View the Utah zoning overlays & bonuses overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Downtown Design Guide in Nearby Cities
How other cities in Utah County handle downtown design guide.