Georgetown, TX Building Safety: Carbon Monoxide Detectors (2026)
Key Facts
- Governing section
- City Code § 8.04.860 (IFC §§ 915.1.1-915.1.5)
- Required in
- Units with fuel appliances, furnaces, attached garages
- Equipment standard
- Alarms per § 915.4 or systems per § 915.5
- Adopting ordinance
- Ord. No. 2023-43, § 13(Exh. K)
- General penalty ceiling
- Up to $2,000.00 per day (safety violation)
Summary
Georgetown's amended Fire Code requires carbon monoxide detection in dwelling units, sleeping units, and classrooms that contain fuel-burning appliances, fuel-burning fireplaces, or forced-air furnaces, and in units attached to private garages. Detection must meet Section 915.3 equipment standards.
915.1.1 Where required. Carbon monoxide detection shall be provided in Group I-1, I-2, I-4 and R occupancies, in Group B fire areas containing an animal housing or care facility, and in classrooms in Group E occupancies in the locations specified in Section 915.2 where any of the conditions in Sections 915.1.2 through 915.1.6 exist. 915.1.2 Fuel-burning appliances and fuel-burning fireplaces. Carbon monoxide detection shall be provided in dwelling units, sleeping units, rooms of animal housing or care facilities where animals are housed or cared for, and classrooms that contain a fuel-burning appliance or a fuel-burning fireplace. 915.1.3 Forced-air furnaces. Carbon monoxide detection shall be provided in dwelling units, sleeping units, rooms of animal housing or care facilities where animals are housed or cared for, and classrooms served by a fuel-burning, forced-air furnace.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 32 | Unified Development Code: Supplement 15).
Full Breakdown
5 for Georgetown. Detection is mandatory in Group I-1, I-2, I-4 and R occupancies, in Group B fire areas with an animal housing or care facility, and in Group E classrooms wherever a fuel-burning appliance, fuel-burning fireplace, or fuel-burning forced-air furnace is present, or where the space is served by one. A furnace exception applies only if detection is placed in the first room served by each main duct leaving the furnace with alarm signals automatically transmitted to an approved location. 4 extends the duty to units in buildings with fuel-burning equipment elsewhere in the structure unless there are no communicating openings, or detection sits in an approved location between the appliance and the protected space.
5 covers units in buildings with attached private garages, with exceptions for units more than one story removed from the garage, garages connected only through an open-ended corridor, or where detection already covers the garage opening. 5, with electronically supervised systems mandatory in Group B animal care fire areas lacking constant animal supervision. These amendments were adopted by Ordinance No. 2023-43, Section 13, Exhibit K.
Violations & Fines
Fire Code violations fall under Georgetown's general penalty in Chapter 1.08: a fine of up to $500.00 for an unspecified violation, rising to as much as $2,000.00 for violations of a rule or ordinance governing safety, zoning, or public health under Section 1.08.010(B). Each day a violation continues is a separate offense. The Fire Marshal's office, as the Code Compliance Agency under Section 8.04.040, administers Fire Code enforcement.
Frequently Asked Questions
Does every Georgetown home need a carbon monoxide detector?
Can a furnace-served room skip its own detector?
What kind of detection satisfies the rule?
Sources & Official References
Other rules in Georgetown
Texas rules heatmap·Compare Georgetown to another location·View the Texas building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Carbon Monoxide Detectors in Nearby Cities
How other cities in Williamson County handle carbon monoxide detectors.