Georgetown, TX Building Safety: Carbon Monoxide Detectors (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Governing section
City Code § 8.04.860 (IFC §§ 915.1.1-915.1.5)
Required in
Units with fuel appliances, furnaces, attached garages
Equipment standard
Alarms per § 915.4 or systems per § 915.5
Adopting ordinance
Ord. No. 2023-43, § 13(Exh. K)
General penalty ceiling
Up to $2,000.00 per day (safety violation)

Summary

Georgetown's amended Fire Code requires carbon monoxide detection in dwelling units, sleeping units, and classrooms that contain fuel-burning appliances, fuel-burning fireplaces, or forced-air furnaces, and in units attached to private garages. Detection must meet Section 915.3 equipment standards.

915.1.1 Where required. Carbon monoxide detection shall be provided in Group I-1, I-2, I-4 and R occupancies, in Group B fire areas containing an animal housing or care facility, and in classrooms in Group E occupancies in the locations specified in Section 915.2 where any of the conditions in Sections 915.1.2 through 915.1.6 exist. 915.1.2 Fuel-burning appliances and fuel-burning fireplaces. Carbon monoxide detection shall be provided in dwelling units, sleeping units, rooms of animal housing or care facilities where animals are housed or cared for, and classrooms that contain a fuel-burning appliance or a fuel-burning fireplace. 915.1.3 Forced-air furnaces. Carbon monoxide detection shall be provided in dwelling units, sleeping units, rooms of animal housing or care facilities where animals are housed or cared for, and classrooms served by a fuel-burning, forced-air furnace.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 32 | Unified Development Code: Supplement 15).

Full Breakdown

5 for Georgetown. Detection is mandatory in Group I-1, I-2, I-4 and R occupancies, in Group B fire areas with an animal housing or care facility, and in Group E classrooms wherever a fuel-burning appliance, fuel-burning fireplace, or fuel-burning forced-air furnace is present, or where the space is served by one. A furnace exception applies only if detection is placed in the first room served by each main duct leaving the furnace with alarm signals automatically transmitted to an approved location. 4 extends the duty to units in buildings with fuel-burning equipment elsewhere in the structure unless there are no communicating openings, or detection sits in an approved location between the appliance and the protected space.

5 covers units in buildings with attached private garages, with exceptions for units more than one story removed from the garage, garages connected only through an open-ended corridor, or where detection already covers the garage opening. 5, with electronically supervised systems mandatory in Group B animal care fire areas lacking constant animal supervision. These amendments were adopted by Ordinance No. 2023-43, Section 13, Exhibit K.

Violations & Fines

Fire Code violations fall under Georgetown's general penalty in Chapter 1.08: a fine of up to $500.00 for an unspecified violation, rising to as much as $2,000.00 for violations of a rule or ordinance governing safety, zoning, or public health under Section 1.08.010(B). Each day a violation continues is a separate offense. The Fire Marshal's office, as the Code Compliance Agency under Section 8.04.040, administers Fire Code enforcement.

Frequently Asked Questions

Does every Georgetown home need a carbon monoxide detector?
Only where the Fire Code triggers apply: a fuel-burning appliance, fireplace, or forced-air furnace in the unit, or an attached private garage. Section 915.1.4 and 915.1.5 list specific exceptions where there are no openings connecting the hazard to living space.
Can a furnace-served room skip its own detector?
Yes, under the Section 915.1.3 exception, if detection is installed in the first room served by each main duct leaving the furnace and the alarm signals transmit automatically to an approved monitored location.
What kind of detection satisfies the rule?
Section 915.3, as amended by Section 8.04.870, requires carbon monoxide alarms meeting Section 915.4 or detection systems meeting Section 915.5; animal care facilities without constant supervision must use an electronically supervised system.

Sources & Official References

Other rules in Georgetown

All Georgetown rules

Texas rules heatmap·Compare Georgetown to another location·View the Texas building safety overview

Get notified when Carbon Monoxide Detectors in Georgetown, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Carbon Monoxide Detectors in Nearby Cities

How other cities in Williamson County handle carbon monoxide detectors.

Cedar Park, TX
Some Restrictions