Lexington, KY Building Safety: Door Locking Hardware (2026)
Key Facts
- Provision
- PM-304.15 Doors (Code of Ordinances § 12-1)
- Requirement
- locks must 'tightly secure' every unit entrance
- Egress doors
- governed separately by Section 702.3
- Enforced by
- Division of Code Enforcement
- Fine
- $100–$2,500 per offense, per day
- Civil-fine alternative
- up to $10,000 per parcel
Summary
Lexington's Property Maintenance Code requires every exterior door at a dwelling or sleeping unit entrance to have a lock that 'tightly secures' it, with egress-door hardware separately governed by the building code's exit-door rules. Code Enforcement treats a broken or missing lock as a maintenance violation carrying the same $100-to-$2,500 fine scale as any other property-maintenance breach.
Doors: All exterior doors, door assemblies, operator systems, and hardware shall be maintained in good condition. Doors and frames installed in exterior openings shall be designed for and intended to be used for that purpose. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Republication | Zoning Ordinance: Republication).
Full Breakdown
15, part of the Section 12-1 Property Maintenance Code (2021 IPMC as locally amended), sets the maintenance and security standard for doors: 'All exterior doors, door assemblies, operator systems, and hardware shall be maintained in good condition. Doors and frames installed in exterior openings shall be designed for and intended to be used for that purpose. 3 of the building code rather than to the property-maintenance rule, since fire-exit doors have their own panic-hardware and non-locking requirements distinct from a unit's entrance locks. 1 penalty structure, a criminal fine of $100 to $2,500 per offense, with each day of continued noncompliance a separate offense, or the alternative civil-fine track of up to $10,000 per parcel plus a $250 administrative inspection cost.
14, which separately requires self-closing, tightly fitting insect screens on swinging doors from April 1 to December 1, a reminder that Section 12-1's door standard covers both security and general maintenance of the same hardware.
Violations & Fines
A landlord or owner who fails to keep entrance-door hardware and locks in working, secure condition faces the Section 12-1 penalty schedule: a $100-to-$2,500 fine per offense with each day a separate violation, or civil fines up to $10,000 per parcel plus a $250 inspection cost under PM-109.4.1's alternative civil-fine track, assessed by the Division of Code Enforcement.
Frequently Asked Questions
Is my landlord required to fix a broken door lock?
Does this rule cover fire exit doors too?
What happens if an owner ignores a door-lock violation notice?